Electrolux Professional WH6-8CV Installation Manual

Washer extractor
Hide thumbs Also See for WH6-8CV:

Advertisement

Installation manual
Washer extractor
WH6–7CV, WH6–8CV, WH6–11CV, WH6–14CV,
WH6–20CV, WH6–27CV, WH6–33CV
Type W3....
438905970/GB, IE
Original instructions
2023.01.03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WH6-8CV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Electrolux Professional WH6-8CV

  • Page 1 Installation manual Washer extractor WH6–7CV, WH6–8CV, WH6–11CV, WH6–14CV, WH6–20CV, WH6–27CV, WH6–33CV Type W3..438905970/GB, IE Original instructions 2023.01.03...
  • Page 3: Table Of Contents

    Contents Contents 1 Safety Precautions ..........................5 General safety information......................6 Commercial use only........................6 Ergonomics certification ......................6 Symbols............................7 2 Warranty terms and exclusions......................8 3 Technical data.............................9 Drawing ............................9 3.1.1 WH6–7, WH6–8, WH6–11 ....................9 3.1.2 WH6–14 ........................10 3.1.3 WH6–20, WH6–27, WH6–33 ..................11 Technical data .........................12 Connections ..........................12 4 Setup ...............................13...
  • Page 5: Safety Precautions

    Installation manual 1 Safety Precautions • Servicing shall be carried out only by authorized personnel. • Only authorized spare parts, accessories and consumables shall be used. • Only use detergent intended for water-wash of textiles. Never use dry cleaning agents. •...
  • Page 6: General Safety Information

    Installation manual LAUNDROMAT/LAUNDERETTE MENCH CAMPING/MARINA OTHER SELF SERVICE – This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowl- edge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 7: Symbols

    Installation manual In case several machines are managed by the same operator the repetitive movements will increase and as a conse- quence of this the related biomechanical risk will increase exponentially. Follow the below recommendations to avoid, as much as possible, operators acquiring bodily injury. •...
  • Page 8: Warranty Terms And Exclusions

    Warranty will be applicable where the customer has used only genuine spare parts and has performed maintenance in accordance with Electrolux Professional user and maintenance documentation made available in paper or elec- tronic format. Electrolux Professional strongly recommends using Electrolux Professional approved cleaning, rinse and descaling agents to obtain optimal results and maintain product efficiency over time.
  • Page 9: Technical Data

    Installation manual 3 Technical data 3.1 Drawing 3.1.1 WH6–7, WH6–8, WH6–11 fig.X01114 Display Door opening, WH6–7, WH6–8: ⌀ 310 mm, WH6–11: ⌀ 365 mm Detergent container Cold water Hot water Cold/Hot water or Re-used water with network pressure (option) Re-used water from tank/pump or Liquid detergent supply Drain Liquid detergent supply Electrical connection...
  • Page 10: Wh6-14

    Installation manual 3.1.2 WH6–14 fig.X01116 Display Door opening, WH6–14: ⌀ 395 mm Detergent container Detergent container (option) Cold/Hot water (Detergent container) Cold water Hot water Cold/Hot water or Re-used water with network pressure (option) Re-used water from tank/pump or Liquid detergent supply Drain Liquid detergent supply Electrical connection...
  • Page 11: Wh6-20, Wh6-27, Wh6-33

    Installation manual 3.1.3 WH6–20, WH6–27, WH6–33 fig.X01115 Display Door opening, WH6–20, WH6–27, WH6–33: ⌀ 435 mm Detergent container Detergent container (option) Cold/Hot water (Detergent container) Cold water Hot water Cold/Hot water or Re-used water with network pressure (option) Re-used water from tank/pump or Liquid detergent supply Drain Liquid detergent supply Electrical connection...
  • Page 12: Technical Data

    Installation manual 3.2 Technical data WH6–7 WH6–8 WH6–11 WH6–14 WH6–20 WH6–27 WH6–33 Weight, net Drum volume litres Drum diameter Drum speed during wash Drum speed during extraction 1245 1245 1165 1113 1054 1007 1007 G-factor, max. Heating: Electricity Heating: Steam Heating: Hot water Frequency of the dynamic 20.8...
  • Page 13: Setup

    Installation manual 4 Setup 4.1 Unpacking 4.1.1 WH6–7, WH6–8, WH6–11 Removal of the bolts between the machine and pallet Remove the front and rear panel. fig.X01120F Remove the bolts between the machine and pallet. fig.X01121 Remove the machine from the pallet. Note! When moving the machine, handle it with care.
  • Page 14 Installation manual Removal of the transport securities When the machine is placed in final or close to final position, remove the four transport supports. Save the transport supports if the machine needs to be moved in the future. Note! Once the transport supports have been removed, handle the machine carefully to avoid damage to the sus- pension components.
  • Page 15: Wh6-14, Wh6-20, Wh6-27, Wh6-33

    Installation manual 4.1.2 WH6–14, WH6–20, WH6–27, WH6–33 Removal of the bolts between the machine and pallet Note! Two persons are recommended for the unpacking. Remove the side panels. Remove the front and rear panel. fig.X01123 Remove the bolts between the machine and pallet. fig.X01124 Remove the machine from the pallet.
  • Page 16 Installation manual Removal of the transport securities When the machine is placed in final or close to final position, remove the four transport supports. Save the transport supports if the machine needs to be moved in the future. Note! Once the transport supports have been removed, handle the machine carefully to avoid damage to the sus- pension components.
  • Page 17: Recycling Instruction For Packaging

    Installation manual 4.2 Recycling instruction for packaging fig.X02400 Fig. Description Code Type Wrapping film LDPE 4 Plastics Corner protection PS 6 Plastics Cardboard packaging PAP 20 Paper Pallet FOR 50 Wood Screw FE 40 Steel FE 40 Steel Plastic bag PET 1 Plastics...
  • Page 18: Siting

    Installation manual 4.3 Siting Install the machine close to a floor drain or open drain. The machine should be positioned so that there is plenty of room for working, both for the user and service personnel. The figure shows minimum distance to a wall and/or other machines. Failure to respect the prescribed distances will prevent easy access for maintenance and service operations.
  • Page 19 Installation manual WH6–7 WH6–8 WH6–11 WH6–14 WH6–20 WH6–27 WH6–33 Place the machine over the two drilled holes. The holes are at the front of the machine. Level the machine with the feet of the machine. Screw in the feet as much as possible before starting to level the ma- chine.
  • Page 20: Marine Installation

    Installation manual 5 Marine installation The maximum inclination allowed in any direction is 4°. To ensure steadiness of the machine; the machine must be fastened to the floor.
  • Page 21: Water Connection

    Installation manual 6 Water connection All water intake connections to the machine should be fitted with manual shut-off valves and filters, to facilitate instal- lation and servicing. Water pipes and hoses should be flushed clean before installation. The machine shall be connected with new water hoses. Re-used water hoses must not be used. Hoses are to be of an approved type and grade and comply with IEC 61770.
  • Page 22 Installation manual Water pressure: Continuous operating pressure: 50–800 kPa (0.5-80 kp/cm Maximum: 1000 kPa (10 kp/cm Recommended: 200–600 kPa (2–6 kp/cm Note! If the water pressure is below the minimum value, the wash result can not be guaranteed for certain program. For WRAS-approved machines;...
  • Page 23: Connection Of External Dosing Systems

    Installation manual 7 Connection of external dosing systems Depending on which type of dosing system that is going to be connected, follow the instructions enclosed with the dosing system. The following is some preparations that can be made on the machine. 7.1 Jetsave and Dosave 7.1.1 Connection of the tube...
  • Page 24: Drain Connection

    Installation manual 8 Drain connection Connect a 75 mm (50 mm for models WH6–7-WH6–11) pipe or rubber hose to the machine’s drain pipe, ensuring a downward flow from the machine. Avoid sharp bends which may prevent proper draining. The machine may drain in to a drainage through or into a closed drain system. In either case, be sure to comply with all applicable national and local plumbing code provisions.
  • Page 25: Electrical Connection

    Installation manual 9 Electrical connection 9.1 Electrical installation The electrical installation may only be carried out by qualified personnel. Machines with frequency-controlled motors can be incompatible with certain types of earth leakage circuit break- er. It is important to know that the machines are designed to provide a high level of personal safety, which is why items of external equipment such as earth leakage circuit breakers are not necessary but is recommended.
  • Page 26 Installation manual WH6–11 Heating alternative Main voltage Heating power Total power Recommended fuse Electric heated 220-240V 1/1N ~ 50/60 3.0/7.5/10.0 3.1/7.6/10.1 16/32/50 220-240V 3 ~ 50/60 3.0/7.5/10.0 3.1/7.6/10.1 10/20/25 380-415V 3/3N ~ 50/60 3.0/7.5/10.0 3.1/7.6/10.1 10/16/16 440V 3 ~ 50/60 7.5/10.0 7.6/10.1 480V 3 ~...
  • Page 27: Machine Connection With Ferrite

    Installation manual * Total power and recommended fuse does not depend on the heating power in those cases. ** Prepared for 3 ~. 9.3 Machine connection with ferrite 9.3.1 WH6–14, WH6–20, WH6–27, WH6–33 To obtain approved level of EMC, it is mandatory to use the ferrite which is enclosed with above listed models. (Note that this is only valid for those models).
  • Page 28: Machine Connection

    Installation manual 9.4 Machine connection Connect the earth and other wires according to the table. Single-phase connection Three-phase connection 1NAC L2 L3 3N AC L2 L3 1N/1 3N AC L2/N Single phase machines may be powered either by connection between a phase and neutral or by connecting be- tween two phases.
  • Page 29: Connection Of External Functions

    Installation manual 9.6 Connection of external functions 9.6.1 Outputs Depending on machine configuration, the outputs are configured according to the following table: Connection Config. 22A Config. 22B Terminal 12 Steam valve (if dual heating) Steam valve (if dual heating) Terminal 13 Liquid 1 Terminal 14 Liquid 2...
  • Page 30: Inputs

    Installation manual 9.6.2 Inputs Depending on machine configuration, the inputs are configured according to the following table: Connection Config. 22A Config. 22B Terminal 5 Enable start Enable start Terminal 6 Remote start /stop Remote start /stop Terminal 7 Coin 1 Coin 1 Terminal 8 Pause...
  • Page 31: Functions For I/O-Boards

    Installation manual 9.7 Functions for I/O-boards The electrical schematic can be one of the following: 9.7.1 Enable start (22A, 22B) This signal can be used to permit the start of the program when the machine is in standby. Once permission to start has been granted, the signal from the central payment or the booking system must remain active (high) until the machine starts.
  • Page 32: Remote Start/Stop (22A, 22B)

    Installation manual 9.7.2 Remote start/stop (22A, 22B) This signal can be used to start the program when the machine is in standby, to pause the cycle when running and to continue the cycle when paused. The central payment system must provide a pulse to start the program. To receive the feedback signal from the machine, 230V or 24V must be connected to terminal 19.
  • Page 33: External Coin Meter/Central Payment (22A, 22B)

    Installation manual 9.7.3 External coin meter/Central payment (22A, 22B) The signal received from external coin meter must be a pulse between 300–3000 ms (500 ms is recommended) with a minimum pause of 300 ms (500 ms is recommended) between two pulses. Con 112 A122 I/O type...
  • Page 34: Pause (22A, 22B)

    Installation manual 9.7.4 Pause (22A, 22B) This signal can be used to pause the program when running. When the signal is activated, the program will pause for as long as the signal remains active (high), e.g. while waiting for central dosing system to be ready. Con 112 A122 I/O type...
  • Page 35: Dual Heating (22A, 22B)

    Installation manual 9.7.5 Dual heating (22A, 22B) This output is used to activate the steam valve on machines made for dual heating. Con 112 A122 I/O type Function Steam valve (if Dual heating) fig.X01693...
  • Page 36: Trigger Signals For Dosing System Without Saving (22B)

    Installation manual 9.7.6 Trigger signals for dosing system without saving (22B) The following outputs can be used as trigger signals for dosing system or for activation of external pumps. Con 112 A122 I/O type Function 230V +24V fig.X01710...
  • Page 37: Dual Heating And Trigger Signals For Dosing System Without Saving (22B)

    Installation manual 9.7.7 Dual heating and Trigger signals for dosing system without saving (22B) On machines with Dual heating, the trigger signals refer to the internal power (230V). In this case, no other power sources are allowed. Con 112 A122 I/O type Function fig.X01711...
  • Page 38: Converting Heating Elements

    Installation manual 9.8 Converting heating elements 9.8.1 WH6–7, WH6–8 and WH6–11 can be converted from 400-415V 3AC to 230-240V 1AC with reduced power Disconnect the power to the machine. Demount the front panel and remove the cover to the heating elements. Remove the blue cables.
  • Page 39: Wh6-14 Can Be Converted From 380-415V 3N Ac To 220-240V 1N Ac With Reduced Power

    Installation manual 9.8.2 WH6–14 can be converted from 380-415V 3N AC to 220-240V 1N AC with reduced power Disconnect the power to the machine. Demount the cover panel to the electrical connections. Remove the cables that are connected to K21:2 and K22:6. Move the remaining cables from L2 and L3 to L1 or N ac- cording to the figure.
  • Page 40: Steam Connection

    Installation manual 10 Steam connection Inlet pipes connected to the machine must be equipped with a manual shut-off valve to facilitate installation and serv- icing. The connection hose must be of type ISO/1307- 1983 or equivalent. Connection size at filter: DN 15 (BSP 1/2"). Demount the top panel (A).
  • Page 41: Steam Connection For Dual Heating (Option For Wh6-14, Wh6-20, Wh6-27, Wh6-33 )

    Installation manual 11 Steam connection for dual heating (option for WH6-14, WH6-20, WH6-27, WH6-33 ) Inlet pipes connected to the machine must be equipped with a manual shut-off valve to facilitate installation and serv- icing. The connection hose must be of type ISO/1307- 1983 or equivalent. Connection size at filter: DN 15 (BSP 1/2").
  • Page 42 Installation manual Connect the cut wires to connection 11 and 12 on the I/O board. fig.X01689 Connect jumpers between connection 1 and 9 and between connection 2 and 10 on the I/O board. fig.X01690 Steam pressure required: • minimum: 50 kPa (0.5 kp/cm •...
  • Page 43: At First Power Up

    Installation manual 12 At first power up When the installation is complete and the power is connected for the first time you will be forced to make some set- tings. Follow the instructions on the display. When one setting is ready you will automatically enter the next one. If installation is made in a public area, it is only allowed to select the below segmets: APARTMENT AUTO DOSING APARTMENT MANUAL DOSING...
  • Page 44: Function Check

    Installation manual 13 Function check May only be carried out by qualified personnel. A function check must be made when the installation is finished and before the machine can be ready to be used. Open the manual water valves. Start a program. •...
  • Page 45: Disposal Information

    Installation manual 14 Disposal information 14.1 Disposal of appliance at end of life Before disposing of the machine, make sure to carefully check its physical condition, and in particular any parts of the structure that can give or break during scrapping. The machine’s parts must be disposed of in a differentiated way, according to their different characteristics (e.g.
  • Page 48 Electrolux Professional AB 341 80 Ljungby, Sweden www.electroluxprofessional.com...

Table of Contents