Drain Fuel Tank Sump - Hitachi ZAXIS 17U-5N Owner's Manual

Hydraulic excavator
Table of Contents

Advertisement

Drain Fuel Tank Sump

--- as required
1. Park the machine following the same procedures as
described on page 7-7 for preparation for inspection and
maintenance.
2. Remove right access cover (1) by loosening bolts (2).
3. Place a 0.5 liters or larger capacity container under drain
valve (3) to collect the drained water.
4. Open drain valve (3) to drain water and/or sediment.
5. After draining water, securely tighten drain valve (3).
6. Install right access cover (1) with bolts (2).
MAINTENANCE
7-57
2