G. Cooling System
1. Check Coolant Level
2. Check and Adjust Fan Belt Tension
3. Change Coolant
4. Clean Radiator and Oil Cooler
Core
 : Shorten the interval in a dusty work site.
 : Maintenance required only during first time.
* : When genuine Hitachi Long-Life Coolant (LLC) is used, change every two years or 2000 operating hours,
whichever comes first.
IMPORTANT:
 Use soft water as a coolant. Do not use strong acid or alkaline water. Use the coolant with genuine Hitachi
Long-Life Coolant (LLC) mixed by 30 to 50 %. If a coolant mixed with less than 30 % of Hitachi Long-Life
Coolant is used, service life of the cooling parts may be shortened due to damage by freezing or corrosion of
coolant system parts.
 If mineral-rich water is used for coolant, water stain or scale may build up inside the engine or radiator,
causing overheat due to deterioration of coolant performance.
H. Electrical System
1. Battery
2. Replacing Fuses
MAINTENANCE
Parts
ZX17U-5N
ZX26U-5N
Outside
Inside
Parts
Check Electrolyte Level
Check Electrolyte Specific
Gravity
Replace
Quantity
8
50
1
1

2.7 L
(2.9 US gal)
3.1 L
(3.3 US gal)
1
1
When coolant is changed
Quantity
8
50
1
1
-
7-16
Interval (Hours)
100
250
500 1000 2000
Twice a year *
Interval (Hours)
100
250
500 1000 2000
Every month
Every month
As required
Page
7-62
7-63
7-65
7-67
Page
7-70
7-71
7-72

Advertisement