INSTALLATION
Electrical Connection
• The electrical connections must comply with local regulations.
• The data relevant to the voltage and power absorption are indicated
on the rating plate.
• The earthing of this appliance is compulsory by law. The manufacturer
cannot be held responsible for injury to persons or animals or damage
to property arising from failure to comply with these requirements.
• When the appliance is installed, provide a multi-pole circuit breaker
with a contact separation (at least 3 mm) in all poles that provide
full disconnection under overvoltage category III and must be
incorporated in the fixed wiring in accordance with the national
wiring rules.
• After installation, the electric parts must not be accessible.
• For electrical connection, use an H05RR-F cable (see table in product
description sheet).
• The power cable must be long enough for connecting the appliance,
once fitted in its housing, to the power supply.
• The electrical components must not be accessible to the user after
installation.
ELECTRICAL COOKING HOBS WITH SIDE CONTROLS
Connection to terminal board
1. Open the cover of the terminal board and loosen screw A by means of a
tool, as shown in the figure.
2. Unsheathe the cable for about 70 mm.
3. Peel off the internal cables for about 10 mm loosen cable clamp screw B,
and insert the cable in the cable clamp.
• The terminal board has 4 terminals:
1-2 interconnected (line)
3 (neutral)
4 (earth): marked with symbol
4. Connect the cable to the terminal board, following the indications of
the connection diagram punched on the bottom of the cooking hob.
Fasten the cable clamp and close the cover.