Introduction

Scope of Manual

This instruction manual includes installation, maintenance, and parts information for the Fisher 8580 valve, DN50
through DN300 or NPS 2 through NPS 12 (figure 1). Refer to separate instruction manuals for information covering the
power on-off actuator and accessories.
Do not install, operate, or maintain an 8580 valve without being fully trained and qualified in valve,
actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property
damage, it is important to carefully read, understand, and follow all the contents of this manual,
including all safety cautions and warnings. If you have any questions about these instructions, contact
your
Emerson sales office

Description

The 8580 rotary valve offers excellent throttling and quarter-turn performance. An approximately linear flow
characteristic provides precise throttling control. The 8580 valve offers high cycle life and rugged reliability.
Retainer clips provide for versatility to mount and align the same wafer style valve body in different piping
configurations (ASME and EN ratings). The valve body is compatible with PN 10 through PN 40, CL150, and CL300
ratings. Face-to-face dimensions meet EN 558, API 609, and MSS-SP68 standards.
The 8580 rotary valve features an eccentrically-mounted, double-offset disk with either soft or metal seal, providing
capability for enhanced shutoff. The interchangeable sealing technology allows for the same valve body to accept both
soft and metal seals.
www.Fisher.com
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . .
. . . . . . . . .
before proceeding.
Figure 1. Fisher 8580 Valve with 2052 Actuator
and DVC6200 Digital Valve Controller
1
1
1
2
2
4
8
8
12
13
17
20
20
21
W9498-3
8580 Valve
LUGGED STYLE
April 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8580 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fisher 8580

  • Page 1: Table Of Contents

    DN300 or NPS 2 through NPS 12 (figure 1). Refer to separate instruction manuals for information covering the power on‐off actuator and accessories. Do not install, operate, or maintain an 8580 valve without being fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings.
  • Page 2: Educational Services

    Instruction Manual 8580 Valve April 2020 D103300X012 Educational Services For information on available courses for Fisher 8580 valves, as well as a variety of other products, contact: Emerson Automation Solutions Educational Services - Registration Phone: 1-641-754-3771 or 1-800-338-8158 E-mail: education@emerson.com emerson.com/fishervalvetraining...
  • Page 3 Instruction Manual 8580 Valve D103300X012 April 2020 Table 3. Material Temperature Capabilities TEMPERATURE MATERIAL LIMITS EN Materials Valve Body Shaft Bearing Lining and Jacket Seal Packing PTFE or RPTFE PTFE or Graphite –10 to 232 14 to 450 UHMWPE PTFE or Graphite –10 to 93...
  • Page 4: Installation

    EN or ASME standards if not included in EN or ASME pressure/temperature ratings. Maximum allowable inlet pressures for 8580 valve bodies made of CW2M or M35‐2 construction materials are shown in table 4.
  • Page 5 WARNING An 8580 valve body is not necessarily grounded when installed in a pipeline. If the valve is used in a flammable or hazardous atmosphere or for oxygen service, an explosion could result due to a discharge of static electricity from the valve components.
  • Page 6 Instruction Manual 8580 Valve April 2020 D103300X012 Table 5. Stud Bolt Data WAFER STYLE AND LUGGED STYLE WITH THROUGH DRILLED HOLES VALVE SIZE PN 10 PN 16 PN 25 PN 40 No. of Size Dia & No. of Size Dia &...
  • Page 7 Figure 4. Optional Shaft‐to‐Valve Body Bonding Strap Assembly Note Standard packings for the 8580 valve are composed of all conductive packing rings (graphite ribbon packing) or partially conductive packing rings (such as a carbon‐filled PTFE female adaptor with PTFE V‐ring packing) to electrically bond the shaft to...
  • Page 8: Maintenance

    Instruction Manual 8580 Valve April 2020 D103300X012 the valve body for hazardous area service. For oxygen service applications, provide alternate shaft‐to‐valve body bonding according to the following step. 9. For oxygen service applications, attach the bonding strap assembly (key 131, figure 4) to the shaft with the clamp (key 130, figure 4), and connect the other end of the bonding strap assembly to the valve body with the cap screw (key 35).
  • Page 9 D103300X012 April 2020 An ENVIRO‐SEAL packing system is also available with the 8580 valve. To install the ENVIRO‐SEAL packing system in an existing valve, follow the instructions in the instruction manual included with the packing system (D101643X012). To remove packing parts in a valve with the ENVIRO‐SEAL packing system, follow the procedures for valves with the ENVIRO‐SEAL packing system in this section.
  • Page 10 Instruction Manual 8580 Valve April 2020 D103300X012 Figure 5. Packing Arrangement Details GE39986‐A PTFE V‐RING GRAPHITE RIBBON GE39901‐A STANDARD PACKING GE40118‐A GE40113‐A GRAPHITE PACKING SINGLE PTFE PACKING ENVIRO‐SEAL PACKING NOTES: WITH CONDUCTIVE PACKING, THE FEMALE ADAPTOR IN PTFE V‐RING PACKING IS CARBON‐FILLED PTFE.
  • Page 11 Instruction Manual 8580 Valve D103300X012 April 2020 WARNING The edges of a rotating disk have a shearing effect that may result in personal injury. To help prevent such injury, stay clear of the disk edges when rotating the disk (key 3).
  • Page 12: Replacing The Seal Ring Assembly

    Instruction Manual 8580 Valve April 2020 D103300X012 D Install the anti‐blowout ring (key 40) in the groove on the drive shaft (key 10). D Install the packing follower and, if used, the packing flange. D Install the packing flange nuts, and tighten them only far enough to stop leakage under normal operating conditions.
  • Page 13: Replacing The Disk, Shafts, Or Bearings

    Instruction Manual 8580 Valve D103300X012 April 2020 Key numbers in this procedure are shown in figure 11 unless otherwise indicated. 1. Isolate the control valve from line pressure, and relieve pressure from the valve body. Shut off and disconnect all lines from the power actuator.
  • Page 14 Instruction Manual 8580 Valve April 2020 D103300X012 2. Remove the actuator per instructions in separate actuator instruction manuals, then remove the cap screws and nuts (keys 35 and 36). Remove the clamp (key 130, figure 4) if the strap (key 131, figure 4) is used.
  • Page 15 Instruction Manual 8580 Valve D103300X012 April 2020 Disassembly 1. Remove the seal ring assembly according to steps 3 and 4 of the Replacing Seal Ring section on page 12 of this manual. 2. Remove hex nuts, blind flange, gasket, spacer (if present), follower spring seats, and follower spring (keys 19, 17, 16, 15, 9, and 12).
  • Page 16 Instruction Manual 8580 Valve April 2020 D103300X012 installed in the wrong orientation. Orient the position indication mark on the end of the shaft with the face of the disk as shown in figure 8. For assemblies using a two-piece, split shaft, the hole for the follower shaft connection is on‐center.
  • Page 17: Actuator Mounting

    Instruction Manual 8580 Valve D103300X012 April 2020 Figure 8. Sectional of Typical Valve Body ACTUATOR END OF SHAFT CCW DISK ROTATION TO OPEN POSITION INDICATION MARK INDICATES APPROXIMATE DISK POSITION 9. For standard packing, install the packing according to the appropriate instructions presented in step 5 of the Replacing Packing section on page 11 of this manual.
  • Page 18 CAUTION 8580 valve disk rotation is counterclockwise to open (when viewed from the actuator side of the valve body, see figure 8). Rotating the disk (key 3) past the fully closed position will damage the seal ring (key 4). To prevent this damage, use the following procedures: D For actuators with adjustable travel stops, such as a Fisher 2052, 1051/1052 size 33, 1066 or 1066SR actuator, make...
  • Page 19 Figure 10. Lever/Shaft/Disk Orientation with Valve Closed ACTUATOR ROD ACTUATOR ROD END BEARING ACTUATOR LEVER LEVER INDEX MARKS (4) VALVE SHAFT INDEX MARK A3344 TYPICAL ACTUATOR (FISHER 1052) SECTIONAL THROUGH HOUSING MOUNTING MOUNTING MOUNTING MOUNTING ACTUATOR VALVE CLOSED POSITION 1 POSITION 2...
  • Page 20: Parts Ordering

    Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Automation Solutions should not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the performance of the valve, and could cause personal injury and property damage.
  • Page 21: Parts List

    Instruction Manual 8580 Valve D103300X012 April 2020 Parts List Description  15 Spacer  16* Gasket  17 Blind Flange  18 Stud  19 Hex Nut Note  20 Drive Screw  21 Nameplate Contact your Emerson sales office for Part Ordering information.  22 Mfg Label  23* Packing Box Ring...
  • Page 22 Instruction Manual 8580 Valve April 2020 D103300X012 Figure 11. Fisher 8580 Valve Assembly NOTE NOTE NOTE NOTE ∗ ALLOY CONSTRUCTION ∗ PARTS NOT SHOWN: KEY 31, 32, 33, 38, 130, 131 USE ONLY WITH PTFE SEAL RING ∗ NOT USED ON SIZE 4 & 6 WAFER BODIES NOT USED ON SIZE 8 &...
  • Page 23 Instruction Manual 8580 Valve D103300X012 April 2020 Figure 12. Fisher 8580 Seal Assembly Detail FLOW RING CONSTRUCTION SOFT SEAL CONSTRUCTION METAL SEAL CONSTRUCTION ASSEMBLY ASSEMBLY ASSEMBLY GE36048_D_2...
  • Page 24 Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher and ENVIRO-SEAL are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co.