Electrolux 21604 G Operating And Installation Instructions page 12

Table of Contents

Advertisement

TYPE OF GAS
NOMINAL THERMAL
POWER
NATURAL GAS
NOMINAL FLOW
20 mbar
VALUE =
RATE
37.78 MJ/m
3
NOZZLE REFERENCE
Ws - 50.7 MJ/ m
3
LPG GAS
POWER
28-30/37 mbar
NOMINAL FLOW
VALUE =
RATE
49.92 MJ/Kg
NOZZLE REFERENCE
Burner
Auxiliary
Semi-rapid
Rapid
Aeration adjustment none
46
BURNER
POSITION
kW
m
/h
3
1/100 mm
NOMINAL THERMAL
kW
g/h
1/100 mm
Dia. Tap By-pass
1/100 mm
28
32
40
Get other manuals https://www.bkmanuals.com
RAPID
SEMI-RAPID
(large)
(medium)
M A X
MIN
M A X
3.0
0.65
2.0
0.286
0.057
0.190
119
Adjust.
96
2.8
0.65
2.0
202
43.5
144
86
40
71
AUXILIARY
(small)
MIN
M A X
MIN
0.45
1.0
0.33
0.038
0.095
0.028
Adjust.
70
Adjust.
0.45
1.0
0.33
29
72
21,5
32
50
28

Advertisement

Table of Contents
loading

This manual is also suitable for:

20604 g11602 g21602 g

Table of Contents