Operation: Refrigeration - Scotsman NSE650 User Manual

Scotsman nse650 ice machine: user guide
Table of Contents

Advertisement

OPERATION: Refrigeration

Beginning at the compressor, the refrigerant is
compressed into a high temperature gas. The
discharge line directs this gas to the condenser.
At the condenser (air or water cooled) the gas is
cooled by either air or water and it then condenses
into a liquid. This high pressure liquid then goes
through the liquid line to the expansion valve. The
thermostatic expansion valve meters liquid
refrigerant into the evaporator, the volume of liquid
refrigerant depending upon the temperature of the
CONDENSER
FAN
MOTOR
Refrigeration Schematic
LIQUID
DISCHARGE
LINE
LINE
August 1993
evaporator; warmer evaporators get more
refrigerant and colder evaporators get less. At the
evaporator, the refrigerant enters an area of
relatively low pressure, where it can easily "boil
off" or evaporate. As it evaporates, it absorbs heat
from the evaporator and whatever is in contact
with it (such as the water inside it). After the
evaporator, the refrigerant, now a low pressure
vapor, goes through the suction line back to
compressor, where the cycle is repeated.
THERMOSTATIC
EXPANSION
VALVE
COMPRESSOR
Page 13
NSE650
SUCTION LINE
EVAPORATOR
GEAR
MOTOR

Advertisement

Table of Contents
loading

Table of Contents