Led Specifications 2; Cautions And Warnings - Fortinet FortiManager 1000D Quick Start Manual

Table of Contents

Advertisement

LED Specifications 2

FortiManager 1000D
HDD
STA
PWR
CONSOLE
USB
1
2
3
4
1
# LED
State
Amber
Ethernet
1
Flashing Amber Port is transmitting and receiving data.
Ports Activity
Off
Green
Ethernet Ports
1
Amber
Speed
Off
Yellow
SFP Ports
2
Flashing Yellow Port is transmitting and receiving data.
Activity
Off
Orange
2 SFP Ports Link
Off
5
6
7
8
2
Description
Port is active.
Port is not connected.
Port is connected at 1Gbps.
Port is connected at 100Mbps.
Port is connected at 10Mbps or not in use.
Port is active.
Port is not connected.
Port is connected at 1Gbps.
Port is not connected
Page 10
Page 10

Cautions and Warnings

Please review the following cautions and warnings.
Environmental and mounting specifications
Operating Temperature: 0 - 40°C (32 - 104°F)
Storage Temperature: -25 - 70°C (-13 - 158°F)
Humidity: 5 to 95% non-condensing
Operating Altitude: <2250m (7400ft)
Elevated Operating Ambient: If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an environment compatible with
the maximum ambient temperature (T
ma
Reduced Air Flow: Installation of the equipment in a rack should be such that the amount of
air flow required for safe operation of the equipment is not compromised.
Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous
condition is not achieved due to uneven mechanical loading.
Circuit Overloading: Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
Reliable Earthing: Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connections to the
branch circuit (e.g. use of power strips).
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received; including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy, and
if it is not installed and used in accordance with the instruction manual, it may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case the user will be required to correct the interference
at his own expense.
WARNING: Any changes or modifications to this product not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.
) specified by the manufacturer.