102 CERTIFICATE
Declaration of performance according
to Regulation (EU) 305/2011
No. 300-ELAB-2436-EN
PRODUCT
Type
Trade name
Intended area of use Fuel
MANUFACTURER
Name
Address
VERIFICATION
According to DANAK
European standard T est
institute
DECLARED PERFORMANCE
ESSENTIAL CHARACTERISTICS
Fire safety
Fire classification
Minimum distance to flammable
materials
Fire hazard due to burning fuel falling out
Cleanability
Emissions from combustion
Surface temperatures
T emperature on the handle
Mechanical resistance
T emperature in the space for wood storage
Nominal output
Efficiency
Flue gas temperature at nominal output
Flue gas temperature in flue spigot
4 of 32
WESTFIRE ·WF35
Wood burning insert Westfire 35
Heating of rooms in residential buildings
Wood
Westfire APS
Tømrervej 3
6800 Varde. Denmark
System 3
EN 13229:2001/A2:2004/AC:2007
Danish Technological Institute
PERFORMANCE
Pass
Al
Rear; 200 mm (With heat shield)
Side: 200 mm (With heat shield)
Ceiling: 800 mm
Front: 1000 mm
Floor: 300 mm
Corner: 150 mm
Pass
Pass
CO:
0.1069%
Pass
NPD
Pass
NPD
4,6 kW
78,2%
°
260
C
°
311
C
4 of 32
HARMONISED TECHNICAL
SPECIFICATION
EN 13229:2001/A2:2004/AC:2007