● Backup current measurement
If reset while in ACC OFF (Back Up ON) condition, MUTE
terminal goes off 2 seconds later, rather than 15 seconds.
(During this time, the CD mechanism does not function.)
● Special displays while all lights are on
When all lights are on with STANDBY source, if the follow-
ing keys are pressed, the following messages are displayed.
Key pressed briefl y: ROM correction version is displayed
(Display) S Y S _ R OM _ R 1 2 3 4
(Display) P A N _ R OM _ R 1 2 3 4
[FM]
(Display) B O L _ R OM _ R 1 2 3 4
key
When E2PROM is not installed: R OM _ E R R _ _
When not written in: R OM _ R – – – –
When data not matching: R OM _ R ∗ ∗ ∗ ∗
[
]
Key pressed briefl y: AUDIO data initialization
key
(Display) A U D I O _ I N I T
Key pressed briefl y: Forced Power OFF data displayed.
Press and hold: To clear the forced power OFF infor-
mation. (Press and hold for 2 seconds while the forced
power OFF data is displayed.)
[
]
(Display) P O F F _ – – – (No Forced Power OFF)
key
Key pressed briefl y: iPod authentication IC installation
status display
[AUD]
(Display) i P o d _ OK _ (Installation status OK)
key
Key pressed briefl y: Multi-function display
[FNC]
Press and hold: Version & Service information display
key
mode ON
Refer to the Table 1.
[1]~[6]
Key pressed briefl y: Version & Service information dis-
key
play mode ON
(Remote
Refer to the Table 1.
controller)
Key pressed briefl y: CD information display mode ON
[ ] key
Refer to the Table 2.
14
TEST MODE
S E C (Forced Power OFF because of
missing Security Code)
P N L (Forced Power OFF because of
system μ-com and panel com-
munication error)
NG _ (Installation status NG)
Table 1 - Version & Service information display mode
([1]~[6] keys: Remote controller)
Key pressed briefl y: Version is displayed (Switch)
(Display) C 0 8 6 3 W K _ _ S Y S 1 . 2 3
(Display) S T Y P E : x x _ P A N 1 . 1 1
(Display) P T Y P E : x _ _
(Display) 9 B 3 0 _ V x x x x
↓↑: Switch with the remote controller [1] key or [
or [
] key.
∗ "STYPE" indicates destination of system μ-com
[1]
and "PTYPE" indicates destination of panel μ-com,
key
and they display the status of destination terminal
in real-time.
(Display) B T _ V E R : H W x x x _ S W x x x
BT module H/W & S/W Version
(Display) A D D R
BT module Address
[AM]
(Display) P I N
key
BT module PIN Code
Key pressed briefl y: Serial No. is displayed (8 digits)
[2]
key
(Display) S N o _ x x x x x x x x
Key pressed briefl y: Power ON time is displayed.
(Display) P o n T i m _ 0 H x x _
[FM]
(00~50 is displayed for "xx". When less than 1
key
[3]
hour, display by increment of 10 minutes.)
key
(Display)
(00001~10922 is displayed for "xxxxx".)
Key pressed briefl y: CD operation time is displayed.
(Display) C D T i m _ _ 0 H x x _
(00~50 is displayed for "xx". When less than 1
[4]
hour, display by increment of 10 minutes.)
key
(Display)
(00001~10922 is displayed for "xxxxx".)
Key pressed briefl y: Number of CD EJECT times is
[5]
displayed.
key
(Display) E j e C n t _ x x x x x
Key pressed briefl y: Invalid
Press and hold: To clear the service information that
[ ] key
is being displayed. (Press and hold for 2 seconds
while each service information is displayed.)
Key pressed briefl y: Version & Service information
[FNC] key
display mode OFF
]
: x x x x x x x x x x x x
: x x x x x x x x
x x x x x
MAX 10922 (hours)
x x x x x
MAX 10922 (hours)
MAX 65535 (times)