Troubleshooting
Problem
Inaccurate
temperature or
humidity
No rainfall
Inaccurate wind
readings
Display screen
not working
• Make sure both the display and 5-in-1 sensor are
placed away from any heat sources or vents
(see page 10).
• Make sure both units are positioned away from
moisture sources (see page 10).
• Make sure 5-in-1 sensor is mounted at least 1.5 m
(5 ft) off of the ground.
• Calibrate indoor and outdoor temperature and
humidity (see page 19).
• Check to ensure the rain gauge stabilizer (plastic tab)
has been removed from the bottom of the sensor (see
page 7).
• Clear debris, such as leaves, out of the rain collector
funnel and debris screen.
• Calibrate the Rain Gauge (see page 20).
• What is wind reading being compared to? Pro
weather stations are typically mounted at 9 m (30 ft)
high or more. Make sure to compare data using a
sensor positioned at the same mounting height.
• Check location of the sensor. Ensure it's mounted a
minimum of 1.5 m (5 ft) in the air with no obstructions
around it (within several feet).
• Ensure wind cups are spinning freely. If they hesitate
or stop try lubricating with graphite powder or spray
lubricant.
• Check that the batteries are installed correctly.
Batteries may need to be replaced.
• Reset the display by pressing and holding the CLEAR
RECORD / RESET button, located in the battery
compartment of the display. Date and time will need
to be entered after a reset.
17
Possible Solution