Onboard Charger Programming - Kärcher Windsor Chariot 3 iScrub 26 Operating Instructions Manual

Hide thumbs Also See for Windsor Chariot 3 iScrub 26:
Table of Contents

Advertisement

Onboard Charger (Optional)
Circuit Breaker must be off before unplugging
batteries.
Le disjoncteur doit être coupé avant de débrancher
les batteries.

Onboard Charger Programming

For machines equipped with optional on-board charger.
When replacing batteries, charger programming
changes may be required. If replacing batteries with
same type, (e.g. maintenance free batteries with main-
tenance free) no programming is required. When
batteries with different type (e.g.maintenance free with
wet cell), programming change are required. Failure to
make programming changes may lead to reduced
battery life.
1. Remove upper control panel.
2. Peel back label on charger to access dip switches.
3. Change switches to correct battery type.
DIP DIP DIP
1
2
OFF ON ON
LEAD ACID
ON OFF OFF
DISCOVER AGM
4. Replace charger label and install upper control
panel.
DIP
DIP DIP DIP DIP
3
4
5
6
7
8
ON
OFF ON ON OFF
OFF
OFF ON ON OFF
86395370 Operator Manual - Chariot 3 iScrub 26
Maintenance
33

Advertisement

Table of Contents
loading

Table of Contents