5-4. STANDARD OPERATION DATA
Representative matching
Mode
Capacity
Input
Indoor unit
Phase , Hz
Voltage
Current
Outdoor unit
Phase , Hz
Voltage
Current
Discharge pressure
Suction pressure
Discharge temperature
Condensing temperature
Suction temperature
Ref. pipe length
Intake air temperature
Discharge air temperature
Intake air temperature
SHF
BF
The unit of pressure has been changed to MPa based on international SI system.
The conversion factor is: 1(MPa)=10.2(kgf/cm²)
OCH654D
PLA-ZM100EA.UK
Cooling
W
9,500
kW
2.03
PLA-ZM100EA.UK
1 , 50
230
V
0.47
A
PUZ-ZM100VKA.UK
PUZ-ZM100VKAR1.UK
PUZ-ZM100YKA.UK
PUZ-ZM100YKAR1.UK
1/3 , 50
230/400
V
9.18/3.08
A
2.51
MPa
1.00
MPa
73
°C
43
°C
14
°C
5
m
27
D.B.
°C
19
W.B.
°C
13
D.B.
°C
35
D.B.
°C
24
W.B.
°C
0.73
0.10
PLA-ZM125EA.UK
Heating
Cooling
11,200
12,500
2.47
3.24
PLA-ZM125EA.UK
1 , 50
230
0.45
0.52
PUZ-ZM125VKA.UK
PUZ-ZM125VKAR1.UK
PUZ-ZM125VKAR2.UK
PUZ-ZM125YKA.UK
PUZ-ZM125YKAR1.UK
PUZ-ZM125YKAR2.UK
1/3 , 50
230/400
10.99/3.74
14.33/4.91
15.62/5.36
2.51
2.68
0.72
0.93
80
81
42
44
3
9
5
5
20
27
15
19
40
11
7
35
6
24
0.64
0.123
16
PLA-ZM140EA.UK
Heating
Cooling
Heating
14,000
13,400
3.54
3.61
PLA-ZM140EA.UK
1 , 50
230
0.50
0.66
PUZ-ZM140VKA.UK
PUZ-ZM140VKAR1.UK
PUZ-ZM140VKAR2.UK
PUZ-ZM140YKA.UK
PUZ-ZM140YKAR1.UK
PUZ-ZM140YKAR2.UK
1/3 , 50
230/400
15.99/5.34
18.83/6.27
2.81
2.72
0.73
0.90
92
82
45
45
1
11
5
5
20
27
15
19
44
12
7
35
6
24
0.67
0.14
16,000
4.25
0.64
2.87
0.70
88
47
0
5
20
15
45
7
6