DATA
5-1. REFILLING REFRIGERANT CHARGE (R32: kg)
Service Ref.
PUZ-ZM100VKA.UK
PUZ-ZM100VKAR1.UK
PUZ-ZM100YKA.UK
PUZ-ZM100YKAR1.UK
PUZ-ZM125VKA.UK
PUZ-ZM125VKAR1.UK
PUZ-ZM125VKAR2.UK
PUZ-ZM125YKA.UK
PUZ-ZM125YKAR1.UK
PUZ-ZM125YKAR2.UK
PUZ-ZM140VKA.UK
PUZ-ZM140VKAR1.UK
PUZ-ZM140VKAR2.UK
PUZ-ZM140YKA.UK
PUZ-ZM140YKAR1.UK
PUZ-ZM140YKAR2.UK
5-2. COMPRESSOR TECHNICAL DATA
PUZ-ZM100/125/140VKA.UK
Service Ref.
PUZ-ZM100/125/140VKAR1.UK
PUZ-ZM125/140VKAR2.UK
Compressor model
U-V
Winding
U-W
Resistance
( " )
W-V
OCH654D
10 m
20 m
30 m
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
AVB33FADMT
0.466
0.466
0.466
Piping length (one way)
40 m
50 m
60 m
4.4
4.8
4.4
4.8
4.4
4.8
Additional charge is required for pipes longer
than 30 m.
(Winding temperature at 20°C)
PUZ-ZM100/125/140YKA.UK
PUZ-ZM100/125/140YKAR1.UK
PUZ-ZM125/140YKAR2.UK
AVB33FACMT
1.199
1.199
1.199
14
75 m
100 m
5.2
5.8
6.8
5.2
5.8
6.8
5.2
5.8
6.8
Initial
charged
4.0
4.0
4.0