34/52
Operation
Bosch Rexroth AG, DBA...2X/...E, RE25891-B/10.21
Table 15: Information on the lock nut
Valve type
Wrench size
Tightening torque
7.
Switch off the system, let the pressure decrease, depressurize any provided
pressure accumulators, if applicable. Remove the temporarily installed pressure
gauge and seal the additional M port using the plug screw. Tightening torques see
table 14.
8.
Return any other pressure limiting devices which are installed in the system and
have an impact on channel P and which you have deactivated or removed before
to the normal operating state.
As an alternative to the procedure described above, the safety valve may also be
removed and set to the desired lower response pressure on a test stand.

9.3 Operation with counter pressure in the discharge line

In principle, the safety valve should be operated without counter pressure in the
discharge line, if possible.
The system pressure increases by the counter pressure in the discharge line (port T)
with increasing flow. In this connection, observe the rules AD2000 - data sheet A2,
point 6.3!
To ensure that this increase in system pressure caused by the flow does not exceed
10% of the set response pressure, the admissible flow has to be reduced dependent
on the counter pressure in the discharge line (port T).
DBA...2X/...E
22
10 + 5 Nm