Environmental Specifications; Isa Expansion Slots; Pci Local Bus Expansion Slots - DEC DIGITAL PC 3010 System Reference Manual

Table of Contents

Advertisement

Technical Specifications

Environmental Specifications

Attributes
Operating temperature
Storage temperature
Operating humidity
(noncondensing)
Storage humidity
(noncondensing)
Altitude
Operating
Nonoperating
Nonoperating shock

ISA Expansion Slots

The maximum available +5 V dc current allowable to any ISA expansion slot
depends upon the following parameters:
Power supply capacity
The +5 V dc requirements of the main logic board
The +5 V dc requirements of the peripherals
The power demands of all other slots in use

PCI Local Bus Expansion Slots

Your computer's backplane contains PCI local bus expansion slots. These slots
support:
Universal 3.3 V dc and 5 V dc PCI expansion boards
Standard power PCI expansion slots (up to 25 watts)
Bus mastering
A-4
Specification
10 °C to 40 °C (50 °F to 104 °F)
-40 °C to 66 °C (-40 °F to 150.8 °F)
10% to 90% relative humidity,
maximum wet bulb 40 °C (104 °F)
10% to 95% relative humidity,
maximum wet bulb 65 °C (149 °F)
3,660 m (12,00 ft) maximum
12,200 m (40,000 ft) maximum
30 G, 11 ms halfsine