TROUBLESHOOTING GUIDE ---Dual Fuel / Self-clean / VDSC - VESO 105 - VED0 205---
PROBLEM
A. No Bake, No Broil A-1 House Breaker or fuse open
No Cycle Light, No
Power to Relay #1.
B. No Bake, No Broil B-1 Timed Bake/Broil function switch
No Cycle Light
Power to Relay #1
(Red – Red/Black) B-2 Power Relay #1 Heater circuit open
terminals #1 & #3)
No power to Relay
#1 Heater.
B-3 Open contacts Relay #2 (single / upper
B-4 Open contact Relay #3 (single / upper
B-5 Open Thermostat cycling contacts
B-6 Open High Limit Switch (contacts
C. No Bake Functions C-1 Open Bake Element (see pg #21 for
Broil functions
normally and the
C-2
Cycle Light is on
C-3 Burned Wiring of Terminal connections
D.
D-1 Low Voltage Supply (240 VAC
Poor Baking Results
Broil functions
Normally, Cycle
Light is on.
D-2 Restricted Air Flow through the oven
D-3 No Top Heat from Broil Element.
D-4 Check Use and Care for suggested
PROBABLE CAUSE
set to Timed function (wall ovens)
(Power Relay test procedure pg 24)
oven) (wh/red wire to neutral pins #1
and #7). Open contacts relay #5 (lower
oven). (blue wire to neutral pins #1
and #7)
oven) (red/blu contact #3 to wh/vio
Contact #9) or open contact Relay #6
(lower oven) (Brown contact #3 to wh/
vio contact #9)
#1 and # 2
normally closed)
Open selector switch contacts 1 to L2
(See pg # 22 for selector Switch
contact checks)
required).
cavity.
Open Selector Switch contacts 3 to E
(see Pg #22 for selector switch checks)
baking tips.)
A-1 Reset Breaker or replace fuse
B-1 Set Timed Bake/Broil function
switch to manual.
B-2
Replace Power Relay #1 (Relay
#1 Part# PM010026)
B-3
Replace Relay #2 (single / upper
oven or Relay #5 (lower oven)
(
Relay #2 & #5 part # PM010029)
B-4
Replace Relay #3 (upper oven) or Relay
#9 (lower oven) (Relay PN 010029)
B-5 Replace Thermostat
B-6 Replace High Limit Switch
C-1 Replace Bake Element
C-2 Replace Selector Switch
C-3 Replace or Repair burned wiring and / or
Terminals (spade) connections.
D-1 Inform Customer of requirements.
D-2 Clear restriction from oven vent.
D-3 Rep lace Selector Switch
202 E
CORRECTION