Technical Information
Disconnect the thermocouple from the bottom casing and from the electronic.
Figure 010-7: Thermocouple Removal, Wok Burners
Note:
Carry out the following after reassembly: Leakage Test, Section 020-4.8,
Burning Properties Test, Section 010-4.7, and Automatic Re-Ignition
Test, Section 010-4.9.
4.6
Ignition Electrode Removal
4.6.1
Normal/Fast Burners
1. Disconnect the cooktop from the power supply.
2. Close the gas tap.
3. Cooktop Surface Removal, Section 010-4.1.
4. Remove the two T20 screws securing the appropriate
electrode/thermocouple mounting plate to the burner base (Figure 010-6,
Item 1).
5. Remove the collars securing the electrode (Figure 010-6, Item 3) to the
topside and underside of the mounting plate. Slide the electrode out of the
plate and disconnect it from the transformer.
Note:
Carry out the following after reassembly: Leakage Test, Section 020-4.8,
Burning Properties Test, Section 010-4.7, and Automatic Re-Ignition
Test, Section 010-4.9.
4.6.2
Wok Burners
1. Disconnect the cooktop from the power supply.
2. Close the gas tap.
3. Cooktop Surface Removal, Section 010-4.1.2.
4. Remove the burner cup (Figure 010-7, Item 1) with a 10-millimeter Allen key.
5. Remove the 2 Phillips screws securing the burner to the bottom casing (Figure
010-7, Item 4).
6. Disconnect the ignition electrode connections from the transformer.
7. Pull the electrode (Figure 010-7, Item 3) up and out of the burner to remove.
KM 34xx Gas Cooktops
18