Installation - Rinnai Energysaver 309FT3 Operation And Installation Manual

Table of Contents

Advertisement

Installation

1. Remove the plastic protection cap from the threaded gas inlet located at the rear of the
appliance.
2. Position the appliance gas inlet in line with the gas supply.
3. Attach the gas supply pipe to the appliance gas inlet and tighten (finger tight).
4. On the wall behind the appliance, at a level of approximately the midway of the heater height,
mark the vertical centreline of the heater.
5. Mark the flue penetration position in accordance with the Energysaver flue installation guide.
6. Undo the gas connection, and remove the heater.
7. Cut the flue penetration.
8. Mark out the securing bracket screw holes in accordance with the table below, using the
centreline as reference.
Model
Dim. A
309FT3
250 mm
125 mm either side of CL
559FT3
350 mm
175 mm either side of CL
561FT3
280 mm
140 mm either side of CL
1005FT3 875 mm
437.5 mm either side of CL
9. Attach the two securing brackets supplied to the wall using the two 8 g x 30 mm screws
supplied, or suitable equivalent.
Models: 309FT3, 559FT3, 561FT3 only - install baffle ring
This step is only for the above models using the ESDFK component in a direct flue installation. The
baffle ring is installed to ensure maximum efficiency of the appliance. If it has been misplaced don't
worry, it's not important to the safe and reliable operation of the unit.
1. Unscrew the air intake elbow from the air intake hose, left handed thread, clockwise to undo.
2. Insert the air intake baffle ring into the appliance end of the air intake elbow.
3. Screw the air intake hose back into the air intake elbow, ensuring the air intake baffle ring is
seated flush against the end of the air intake hose.
Dim. B
624 mm
537 mm
B
688 mm
622 mm
A
Securing brackets
C L
Heater centre Line
Floor Level
21