Error Codes - Rinnai Energysaver 309FT3 Operation And Installation Manual

Table of Contents

Advertisement

Error codes

The Energysaver range has built-in technology to continually monitor performance. If a fault occurs
an error message will flash on the digital display on the control panel. This assists with diagnosing
the fault and may enable you to overcome a problem without a service call.
In all cases you may be able to clear the error by turning the heater off and on again. If the error
code remains or returns when the heater is used again, contact Rinnai.
Faults caused by insufficient gas supply, gas quality, installation or operation errors are not covered
by the Rinnai warranty.
Error code
Likely cause
11
Ignition failure
12
Flame failure
14
Filter blockage/overheat
16
Room overheat*
30
Overheat temperature sensor faulty
31-32
Room temperature sensor faulty
33-35
Overheat temperature sensor faulty
40
Sensor sensing tube failure
49
Sensor breakdown
53
Spark sensor faulty
61
Combustion fan faulty
62
Convection fan faulty
70
Faulty ON/OFF switch
71
Faulty solenoids
72
Flame detection circuit fault
73
Communication error
81
Faulty solenoids
99
Flue terminal blocked
* If the unit detects 40 °C for over ten minutes, the unit will stop operating.
Suggested solution
Check gas supply is turned on, turn the
heater OFF then ON again. If the error
persists a service call is required.
As above.
Clean filter(s), if the error continues a
service call is required.
Lower the room temperature below 40 °C.
Service call.
Service call.
Service call.
Service call.
Installer: Confirm commissioning has
been completed in accordance with the
instructions. Ensure that the pressure
check tube is not blocked, pinched or
crushed.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Owner: Check that the flue terminal is free
of any obstructions. If the error persists a
service call is required.
Installer: Confirm commissioning has
been completed in accordance with the
instructions. Check that the flue terminal
is free of any obstructions. Ensure that
the pressure check tube is not blocked,
pinched or crushed.