Electrical Connection; Water Connection; Cooking Accessories - Electrolux PR 700 Installation Operation & Maintenance

Professional food service equipment
Table of Contents

Advertisement

4.

ELECTRICAL CONNECTION

• The connection to the electrical supply must be carried out
according to the standards in force.
• Before carrying out the electrical connection make sure the
voltage and frequency on the data plate correspond to those of
the supply system.
• A protection onnipolar switch must be installed upstream from
the appliance with a suitable capacity and a contact opening
distance of at least 3 mm.
• This switch must be installed in the building's main power
supply line and near the appliance.
• It is important to connect the appliance to an efficient earth
outlet. For this purpose, there is a screw with the symbol G in the
connection terminal board, to which the earth wire is to be
connected. The appliance must be included in an unipotential
system.
This connection is carried out with a setscrew marked E placed
under the appliance. The unipotential wire must have a 10 mm
section.
4.1.
ACCESS TO THE MAIN TERMINAL BOARD (fig. 3)
To gain access to the main terminal board first remove the panel
below the access door:
• Connect the cable to the terminal board "ma1" following the
indications laid down in the wiring diagram attached to the
appliance.
The manufacturer declines all responsability if the accident
prevention standards are not observed.
5.
(fig.3)
The appliance must be supplied with softened drinking water at
0.5 to 5 Fh (French hardness) and at a pressure of between 1.5
to 3 bar.
For correct installation, it is also necessary to ensure that:
• The water-inlet pipe "B" (fig.1) is connected to the water mains
by means of a cutoff cock with a mechanical filter.
Before connecting the filter run off a certain amount of water in
order to remove any eventual ferrous particles from the piping.
5.1.
• Water must be drained from the appliance using a suitable
drainage collector. The steam produced during the drainage
cycle must not blow back onto the appliance.
6.
Rectangular basket kit:
2
Type
"
Round basket kit
Type
Type
(*)
Used with a lower grill
Tank lid
3
9
Get other manuals https://www.bkmanuals.com

WATER CONNECTION

DRAINAGE

COOKING ACCESSORIES

1/3
1/2
:
(*)
1/3
1/6
code-number
927214
code-number
927221
code-number
927212
code-number
927213
code-number
927219
code-number
927218

Advertisement

Table of Contents
loading

Table of Contents