Note (1) The number of flashes when in the Service Mode do not include the 1.5 second period when the lights light up at first (start signal). (See the example
shown below.)
ON
RUN light
(10's digit)
OFF
ON
TIMER light
(1's digit)
OFF
Notes
(2) Abnormal Stop:
- Is not displayed. (automatic recovery only)
○ Displayed.
If there is a (
reached the number of times in (
If no (
Notes
(3) Automatic Recovery: - Does not occur
○ Automatic recovery occurs.
(d) Remote control information tables
1) Operation switching
Display pattern when
in service mode
Operation switching
RUN light
(Operation switching)
0
1
2
3
4
* If no data are recorded (error code is normal), the information display in the remote control becomes as follows.
Remote control setting
Operation switching
Fan speed switching
(Example): Operation switching, fan speed switching, cooling HI
ON
RUN light
(10's digit)
OFF
ON
TIMER light
(1's digit)
OFF
In the case of current cut (example: stop code "42")
The RUN light (10's digit) flashes 4 times and the TIMER light (1's digit) flashes 2 times.
4 10 + 2 1 = 42
From the table, read the instructions for error code 42, "Current cut".
1.5 sec.
0.5 sec.
0.5 sec.
11-second interval
) displayed, the error display shows the number of times that an automatic recovery occurred for the same reason has
).
) is displayed, the error display shows that the trouble has occurred once.
when there is an
abnormal stop
AUTO
DRY
COOL
FAN
HEAT
Display when error code is normal.
1.5 sec.
0.5 sec.
0.5 sec.
11-second interval
47
-
2) Fan speed switching
Display pattern when
Fan speed
in service mode
switching when
there is an
TIMER light
abnormal stop
(Fan speed switching)
0
2
3
4
6
HI POWER
7
AUTO
AUTO
-
'13 • SRK-T-140
AUTO
HI
MED
LO
ECONO