Outdoor Units - Mitsubishi Heavy Industries SRC25ZMP-S Technical Manual

Table of Contents

Advertisement

TO INDOOR UNIT
[
]
2
POWER WIRES
1
N
SIGNAL WIRE
3
POWER SOURCE
~220-240V 50Hz
L
N
TB
Power cable, indoor-outdoor connecting wires
MAX running current
Power cable size
Power cable length
Model
(A)
(mm
2
25
9
2.0
35
45
14
2.0
The specifications shown in the above table are for units without heaters. For units with heaters, refer
to the installation instructions or the construction instructions of the indoor unit.
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen
along the regulations in each country.
The cable specifications are based on the assumption that a metal or plastic conduit is used with no
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation
in effect in each country.
L
T1 T2
t゜
250V 15A
R.IN
(BK)
1
NOISE
2
FILTER
S.IN
(WH)
3
(Y/G)
C-2
(RD)
G1
(Y/G)
CN20S
CNTH
20S
TH1 TH2 TH3
indoor-outdoor
Earth wire size
wire size x number
(m)
(mm
2
32
1.5mm
x 4
1.5
2
18
1.5mm
2
x 4
1.5
F2
+
+
250V 20A
F3 250V 1A
PAM
F4
CIRCUIT
250V 10A
SWITCHING POWER
CIRCUIT
CNEEV
M
EEV
Item
Description
CM
Compressor motor
CN20S
Connector
CNEEV
CNFAN
CNTH
EEV
Electric expansion valve(coil)
FMo
Fan motor
L
Reactor
TB
Terminal block
TH1
Heat exchanger sensor(outdoor unit)
TH2
Outdoor air temp. sensor
TH3
Discharge pipe temp. sensor
20S
Solenoid coil for 4 way valve
PWB ASSY
POWER
TRANSISTOR
P
U
(RD)
U
M
V
(WH)
V
3~
W
(BK)
W
N
CM
M
CNFAN
FMo
Mark
Color
BK
Black
OR
Orange
RD
Red
WH
White
Y
Yellow
Y/G
Yellow/Green