INSTALLATION OF INDOOR UNIT
Installation of Installation board
Fixing of installation board
Look for the inside wall structures (Intermediate support or pillar
and firmly install the unit after level surface has been checked.)
Level position (2 locations)
Mating mark for
level surface
Drilling of holes and fixture of sleeve (Option parts)
When drilling the wall that contains a metal lath, wire lath or metal plate, be sure to use pipe hole sleeve sold separately.
Top
ø65
Indoor side
Outdoor side
Drill a hole with whole core drill.
In case of rear piping draw out, cut off the lower
and the right side portions of the sleeve collar.
Preparation of indoor unit
Mounting of connecting wires
① Remove the lid.
② Remove the terminal cover.
③ Remove the wiring clamp.
④ Connect the connecting wire securely to the terminal block.
1) Connect the connection wire securely to the terminal block. If
the wire is not affixed completely, contact will be poor, and it is
dangerous as the terminal block may heat up and catch fire.
2) Take care not to confuse the terminal numbers for indoor and
outdoor connections.
⑤ Fix the connecting wire by wiring clamp.
⑥ Attach the terminal cover.
⑦ Attach the lid.
Installing the support of piping
Piping is possible in the rear, left, left rear,
left downward, right or downward direction.
Right
Rear
Downward
Left
Left rear
Left downward
○Adjustment of the installation board in the horizontal
direction is to be conducted with four screws in a
temporary tightened state.
394
○Adjust so the board will be level by turning the
board with the standard hole as the center.
Standard hole
Thickness of the wall +1.5 cm
Indoor side
In case of faulty wiring connection, the indoor unit stops,
and then the run lamp turns on and the timer lamp blinks.
Use cables for interconnection wiring to avoid loosening of the
wires. CENELEC code for cables Required field cables.
H05RNR4G1.5 (Example) or 245ICE57
H
Harmonized cable type
05
300/500 volts
R
Natural-and/or synch. rubber wire insulation
N
Polychloroprene rubber conductors insulation
R
Stranded core
4 or 5
Number of conductors
G
One conductor of the cable is the earth conductor
(yellow/green)
1.5
Section of copper wire (mm
Matters of special notice when piping from left or central/rear of the unit.
[Top view]
Left-hand-sided piping
Piping in the right rear direction
Piping in the left rear direction
Piping in the left direction
Relation between setting plate and indoor unit
INSTALLATION SPACE (INDOOR UNIT)
Space for
service
Turn to
tighten
Piping for Liquid Model SRK25~45, DXK09~15 : ø6.35
Piping for Gas
Putty
Installed state
Outdoor side
CAUTION
○Perform wiring, please take care of connecting the
2
)
terminal number of outdoor unit terminal block.
Right-hand-sided piping
Since this air conditioner has
been designed to collect dew
drops on the rear surface to
the drain pan, do not attach
the power cord above the
gutter.
Piping in the right direction
(FRONT VIEW)
indoor unit
Space for
service
50
Installation board
100
187.5
394
187.5
157
455
157
130.5
508
130.5
55
55
Piping for Gas 359.5
Piping for Liquid 427.5
Piping hole (ø65)
Drain hose 530 (ø16)
Piping hole (ø65)
Model SRK25/35, DXK09/12 : ø9.52
( Unit : mm )
Model SRK45, DXK15
: ø12.7
Terminal block
The screw of the lid
is tightened securely.
Terminal cover
Lid
Screw
Clamp
Gutter
Pipe accommodating section
INSTALLATIO
Fixing of outdoor
○Make sure that the unit is
Fix the unit to stable base
○When installing the unit at
it could be toppled by stro
firmly with foundation bolts
Electric wiring work
○Perform wiring, making wir
conform to terminal numbe
block.
○Connect using ground scre
○Always perform grounding s
○Connect a pair bearing a co
○In cabling, fasten cables sec
○Grounding terminals are pro
Always u
CAUTION
to preven
Ea
Phase
Model
SRK25 / DXK09
Single
15
SRK35 / DXK12
-phase
0.1
SRK45 / DXK15
○The specifications shown in
installation instructions or th
○Switchgear or Circuit breake
regulations in each country.
○The cable specifications are
three cables contained in a
please follow the internal ca
CONNECTIO
Preparation
Keep th
n I
d
o
r o
(Do not turn)
Remo
○Remove the flared nuts.
(on both liquid and gas sides)
CAUTION
Do n
Flaring work
Measurement