ECO-Function
Summer/winter heating limit
The summer / winter heating limit is
used to switch the heating on and off in
the course of the year, depending on
temperature conditions. In automatic
mode, switching on / off takes place
automatically, so there is not need for
the user to do this manually. By chang-
ing the setting, the respective periods
of time will be shortened or extended.
Increase:
Winter operation will start earlier.
Summer operation will start later.
Decrease:
Winter operation will start later.
Summer operation will start earlier.
• The function is not active in operating
mode Comfort
• The display shows ECO
• To incorporate the building´s thermal
dynamics, the outside temperature is
attenuated
24-hour heating limit
The 24-hour heating limit is used to
switch the heating on and off in the
course of the day, depending on the
outside temperature. This function is
used primarily during spring and au-
tumn to respond to short-term tempera-
ture variations.
By changing the value entered, the
respective heating periods will be short-
ened or extended.
Increase: Heating mode will start
earlier. Changeover to ECO later.
Decrease: Heating mode will start later.
Changeover to ECO earlier.
• The function is not active in operating
mode Continuously comfort tempera-
ture.
• The display shows ECO
• To give consideration to the building´s
thermal dynamics, the outside tempera-
ture will be attenuated.
Andrews COMBIfl o
Line no.
Operating line
HC1
HC2
730
1030
Summer/winter heating limit
732
1032
24-hour heating limit
733
1033
Ext'n 24-hour heating limit
Legend
SWHG
t
T
TAged
Example
Setting line
Comfort setpoint (TRw)
24-hour heating limit (THG)
Changeover temperature (TRw-THG) heating OFF
Switching differential (fixed)
Changeover temperature heating ON
Ext'n 24-hour heating limit
The 24-hour heating limit is extended
by giving consideration to the composi-
te outside temperature when the hea-
ting is switched on. Alternatively, the
heating can be switched on again only
dependent on the current outside tem-
perature.
No
The 24-hour heating limit applies only
dependent on the current outside tem-
perature.
10
Summer / winter heating limit
Days
Temperature
Attenuated outside temperature
Yes
The 24-hour heating limit applies as
described under 24-hour heating limit,
depending on both the current and the
composite outside temperature.
.
Factory setting
20°C
-3°K
Yes
E.g.
22°C
-3°C
= 19°C
-1°C
= 18°C