Captium data hub

Advertisement

IDEX FIRE AND SAFETY
E3 Connect – Tool Alerts
Alert
Source
Tool
Drop Alert
• Early Fault Detection and Reduction of Downtime 
Tool
Tool Roll Alert
Tool
Tool Submerged 
Tool
Tool Submerged in Salt 
Water
Tool
Tool Improperly used 
in Salt Water
Tool
Tool Submerged for 
Extended Time
MOSFET Temp is 
Tool
Critical
No Energy on Motor
Tool
Tool
Tool Efficiency Alert
33
Description
Tool has fallen from a critical height and may been damaged
The cutter or combi has been rotated over a 15⁰ angle 
Tool has been submerged in fresh water
Tool has been submerged in salt water
Tool with a freshwater battery is submerged in salt water
Tool was submerged in for over 60 Min
Electronic tool components have reached a critical temperature 
value
The battery can no longer power the tool
Energy consumption too high/low creating insufficient pressure for 
proper function.
Suggested Action
Inspect tool for cracks and leaks
Review blades and links for cracks. Check center bolt torque
Rinse, clean and treat tool to prevent corrosion
Rinse, clean and treat tool to prevent corrosion
Inspect tool and battery contacts for corrosion and change out 
components if found
Inspect tool and battery contacts for corrosion and change out 
components if found
Inspect tool for root cause
Check electronic contacts
Inspect mechanical components 

Advertisement