Advertisement

Quick Links

TAS12/IntraQ Direct Connect
Advanced Configuration Guide
PUD4246R5-0 Version 4.0
Alvarado Manufacturing Company, Inc.
12660 Colony Street, Chino, CA 91710
Telephone: (909) 591-8431
Fax: (909) 628-1403
support@alvaradomfg.com
www.alvaradomfg.com
PUD4246R5-0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALVARADO TAS12/IntraQ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dormakaba ALVARADO TAS12/IntraQ

  • Page 1 TAS12/IntraQ Direct Connect Advanced Configuration Guide PUD4246R5-0 Version 4.0 Alvarado Manufacturing Company, Inc. 12660 Colony Street, Chino, CA 91710 Telephone: (909) 591-8431 Fax: (909) 628-1403 support@alvaradomfg.com www.alvaradomfg.com PUD4246R5-0...
  • Page 2: Table Of Contents

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Contents Preface..................................3 Document Overview..............................3 Support................................... 3 Changing Configuration from the Device........................4 Navigate to the Device Configuration Screen......................4 Device Configuration Options.
  • Page 3: Preface

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Preface Document Overview This document is meant to provide users with detailed information about the various configuration options available for Alvarado TAS12 and IntraQ Direct Connect devices. The document is current up to TAS12 DirectConnect version 1.3.1.
  • Page 4: Changing Configuration From The Device

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Changing Configuration from the Device Most Direct Connect configuration options are in the configuration text files detailed in the following sections. However, you can adjust some configuration options from the device itself. Navigate to the Device Configuration Screen 1.
  • Page 5: Device Configuration Options

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Device Configuration Options 1. All the configuration options on this screen can also be configured int the tas.txt file. See the TAS.txt File section below on page 6. •...
  • Page 6: Tas.txt File

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS.txt File Network Setting Name Default Description SITE NAME= Text string identifier that is sent to the validation server with each validation request that identifies the device’s location. SERVER URI= http://192.168.0.100/ URI of the validation server.
  • Page 7: Json Interface Fields

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 JSON Interface Fields Setting Name Default Description INTERFACE= 1: Uses SOAP XML interface 2: Uses JSON interface AUTHENTICATION= Basic Basic authentication header used when sending YWRtaW4vYWx2YXJhZG8= requests.
  • Page 8 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Setting Name Default Description SCREEN TIMEOUT= Time in seconds that the device will remain idle on the Operator Menu or Operator Login screens before it returns to the previous screen. The timeout applies individually to each screen.
  • Page 9: Other

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Setting Name Default Description LED TIME SLOW ON= Time in milliseconds the LED remains on in Slow Flash Mode. LED TIME SLOW Time in milliseconds the LED remains off in Slow Flash OFF= Mode.
  • Page 10: Amanda.txt File

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Amanda.txt File Amanda GPIO Setting Name Default Description ACTIVATION RELAY The output port for the activation relay. OUTPUT= GREEN LED The output port for the green attendant LED. OUTPUT= YELLOW LED The output port for the yellow attendant LED.
  • Page 11: Edm

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Setting Name Default Description KEYBOARD PORT= RS232 port used by keyboard in the range 1 – 4. To disable keyboard set to 0. To enable keyboard, set value to port not used by scanner.
  • Page 12: Rfid-Nfc.txt

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 RFID-NFC.txt Setting Name Default Description RFID= False True: Enables support for the RFID reader. The device uses RFID scans as Delivery ID or ticket, depending on the RFID IS TICKET field.
  • Page 13 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Setting Name Default Description RFID CODE Defines a delimiter character used when reading DELIMITER= multiple blocks of data. The TAS12 device will read up to the RFID CARD LENGTH or RFID CODE DELIMITER, whichever comes first.
  • Page 14: Messages.txt File

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Messages.txt File The messages.txt file can be updated automatically by the server when the device first comes online. The file contains a list of messages that are displayed on the Ticket Validation screen depending on the response code returned by the scan.
  • Page 15: Screen Images

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Screen Images The images shown in the tables below are for TAS12 devices. IntraQ devices have the same images and file names, but different dimensions. TAS12 Go.bmp IntraQ Go.bmp Default Images The bitmap files identified and described below are included by default when TAS12 units ship from Alvarado.
  • Page 16 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Bitmap Image File Name Description Response Code scan.bmp The default “idle” image when the device is waiting for the patron to scan a barcode. wait.bmp Displays when the device is launching the TAS application or when it is processing information.
  • Page 17: Images And Response Codes

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Images and Response Codes Each response code can have its own unique bitmap associated with it. When a ticket scan returns a response code, the TAS12 displays the associated bitmap image on the screen. For example, Alvarado uses response code 51 when a scanned ticket is not found in the database.
  • Page 18: Image File Guidelines

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Image File Guidelines Observe the following guidelines when creating custom bitmaps: • Bitmap files for TAS12 devices must have pixel dimensions 480 (W) x 640 (H). Bitmap files for IntraQ devices must have pixel dimensions 640 (W) x 480 (H).
  • Page 19: Sound Files

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Sound Files Default Sound Files The sound files described below are included by default when TAS12 units ship from Alvarado, unless alternative sounds are provided by the customer. If a sound file has a name that includes a number, that sound plays for that response code number.
  • Page 20: Appendix 1 - Symbologies

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Appendix 1 – Symbologies The table below shows the syntax for the RECEIPT SYMBOLOGY field. For your convenience, the most commonly used code characters have been provided. TAS12 devices use the Honeywell 3320g barcode imager.
  • Page 21: Revision History

    TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Revision History Revision Date Author Revision History/Description 5/22/2018 D Bohannon Original Document 11/21/2019 D Bohannon Updated for current version of software. 8/6/2020 D Bohannon Added SOAP XML information. 5/24/2021 D Bohannon Updated to current configuration file content.
  • Page 22 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 TAS12/IntraQ Direct Connect Advanced Configuration Guide 4.0 Alvarado Manufacturing Company, Inc. 12660 Colony Street, Chino, CA 91710 Telephone: (909) 591-8431 Fax: (909) 628-1403 support@alvaradomfg.com www.alvaradomfg.com © 2021 Alvarado Manufacturing Company, Inc. This work may not be reproduced, published or redistributed, in whole or in part, without the express prior written permission of Alvarado.

Table of Contents