Bluetooth Operation - VEVOR XMZ-D1 Manual

Diesel heater
Table of Contents

Advertisement

Flame out due to
E-08
lack of oil
Overheat
E-09
protection sensor
Secondary startup
E-10
failed
Search and download the corresponding APP name "airHeaterBle" in IOS or
Android APP store, then please follow the below step to connect and control the
heater with a mobile phone.
jammed.
Check whether the fan plug is loose and
2.
falsely connected.
The fan is faulty; replace the fan.
3.
Check whether the wind wheel induction
4.
magnet is missing or has
the wrong polarity.
Check whether the main board wind speed
5.
sensor is normal.
The main board is faulty; replace the main
6.
board.
Checking the fuel tank for lack of oil.
1.Detect whether the outlet air temperature
sensor connector is loose and connected
falsely. 2.The air outlet sensor is faulty, replace
the main board.
3.The main board is faulty; replace the main
board.
Check whether the oil pump works.
1.
Check whether the interfaces of the oil circuit
2.
are hanging wax and blocked.