Indoor unit
Indoor unit

Fixing Installation Plate

The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using Horizontal meter.
2. Measure the wall and mark the centerline.
It is also important to use caution concerning the
location of the installation plate. Routing of the
wiring to power outlets is through the walls
typically. Drilling the hole through the wall
for piping connections must be done safely.
SB Chassis (9k, 12k)
SC Chassis (18k, 24k)
Drill a Hole in the Wall
• Drill the piping hole with a ø70mm hole core
drill. Drill the piping hole at either the right or
the left with the hole slightly slanted to the
outdoor side.
10 Air Conditioner
Unit Outline
442
Ø70
Left rear piping
133
175
Unit Outline
460
Ø65
Left rear
piping
69
105
Installation Plate
Chassis
Hook
SB Chassis
Place a level on raised tab
442
Installation Plate
Place a level on raised tab
570
Installation Plate
Measuring Tape
Measuring Tape
Hanger
Indoor
Type "A" Screws
Installation Plate
Chassis
SC Chassis
Hook
Ø70
Right rear piping
95
217
Ø65
Right rear
piping
56
207
WALL
Outdoor
Type "A" Screws