Fixing Installation Plate

The wall you select should be strong and solid
enough to prevent vibration
1
Mount the installation plate on the wall
with type "A" screws. If mounting the unit
on a concrete wall, use anchor bolts.
- Mount the installation plate horizontally
by aligning the centerline using a level.
Installation Plate
<Type 1>
Installation Plate
Chassis
Hook
<Type 2>
Installation Plate
Chassis
Hook
<Type 3>
Chassis
Hook
2
Measure the wall and mark the centerline.
It is also important to use caution
concerning the location of the installation
plate-routing of the wiring to power outlets
is through the walls typically. Drilling the
hole through the wall for piping
connections must be done safely.
INSTALLATION OF INDOOR, OUTDOOR UNIT
Type "A" Screws
Type "A" Screws
Type "A" Screws
Capacity
Indoor Type
(kBtu/h)
Wall mounted
9,12
/ART COOL
18, 24
Mirror
<Type 1>
Place a level on raised tab
Unit Outline
442
Ø 65
Installation Plate
133
175
<Type 2>
Place a level on raised tab
Unit Outline
460
Ø 65
Installation Plate
Left rear
Measuring Tape
piping
69
105
Measuring Tape
Hanger
<Type 3>
460
Unit
Outline
Ø 65
Place a level on raised tab
Installation plate
Left Rear
Piping
184
220
9
Type
1
2,3
442
Ø 65
95
217
(Unit : mm)
570
Ø 65
Right rear
piping
56
207
(Unit : mm)
567
Ø 65
Right Rear
156
Piping
307
(Unit : mm)