Panther Condens
20/26 KKV-CS/1 (N-INT)
25/31 KKV-CS/1 (N-INT)
30/35 KKV-CS/1 (N-INT)
25 KKO-CS/1 (N-INT)
30 KKO-CS/1 (N-INT)
en Operating instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 20/26 KKV-CS/1 and is the answer not in the manual?

Questions and answers

Jana Meinel
May 25, 2025

Kde se nachazi napousteci kohout zajistujici spravny tlak v topnem systemu. Chci odvzdusnit radiatory.

1 comments:
Mr. Anderson
May 26, 2025

To ensure the correct pressure in the Protherm 20/26 KKV-CS/1 heating system, ask a competent person where the filling tap is located.

This answer is automatically generated

Summary of Contents for Protherm 20/26 KKV-CS/1

  • Page 1 Panther Condens 20/26 KKV-CS/1 (N-INT) 25/31 KKV-CS/1 (N-INT) 30/35 KKV-CS/1 (N-INT) 25 KKO-CS/1 (N-INT) 30 KKO-CS/1 (N-INT) en Operating instructions...
  • Page 2: Table Of Contents

    Operating instructions Guarantee and customer service ........14 Contents 10.1 Guarantee........14 10.2 Customer service......14 Safety ..........3 Appendix ..........15 Intended use ........3 Fault codes......... 15 Qualification ........3 Troubleshooting ......15 General safety information..... 3 Notes on the documentation ..6 Product description.....
  • Page 3: Safety

    1 Safety experience and knowledge if they have been given supervi- 1.1 Intended use sion or instruction concerning The product is intended as a use of the product in a safe way heat generator for sealed heat- and understand the hazards in- ing installations and for do- volved.
  • Page 4 – The product itself bells, telephones or other – to the gas, supply air, water communication systems in the building. and electricity supply lines – to the entire flue system ▶ Close the emergency control – to the entire condensate dis- valve or the main isolator.
  • Page 5 ▶ Only fill the heating installa- tion with suitable heating wa- ter and, in cases of doubt, ask a competent person about this. 1.3.5 Legionella ▶ Have a competent person in- form you about the measures that should be taken to pro- tect against Legionella in your installation.
  • Page 6: Notes On The Documentation

    These instructions apply for the following – Navigating through the menu products only: structure Product article number – Reducing or increasing the set value 20/26 KKV-CS/1 0010025162 – Navigating to individual num- 25/31 KKV-CS/1 0010025163 bers and letters 30/35 KKV-CS/1...
  • Page 7: Serial Number

    4 Function Symbol Meaning eco function activated 4.1 Operating concept Setting the time: The adjustable values and menu items – Permanently on: Time is set – Flashing: The time must be can be changed using the reset buttons. Warning Each value change must confirmed using Fault in the product: .
  • Page 8: Setting The Time

    4.2 Setting the time 4.4 Heating mode In heating mode, the rooms are heated up Note in accordance with your settings. When restarting following a power cut or an interruption to the power 4.4.1 Setting the heating flow supply, the time, date and year are temperature not stored.
  • Page 9: Dhw Mode

    4.4.2 Setting the parametrisation for 4.4.4 Switching programmed the heating times heating mode on/off In the basic display, press and hold Press ◁ The following display view appears ◁ In the display, On is displayed for a few seconds and appears in the basic display.
  • Page 10: Displaying The Product's Energy Consumption

    Condition: Control connected Press to switch eco mode ▶ Set the required domestic hot water on or off. temperature on the control (→ Control Confirm by pressing operating instructions). ◁ is shown on the display when 4.5.2 Switching off the domestic hot the eco mode is activated.
  • Page 11 4.6.1 Calling up the end user level Press the button until the sym- bol is displayed. Set the code for the end user level and confirm by pressing – Code for end user level: 00 4.6.2 Calling up the product's energy consumption 01 Daily energy 04 Previous year's...
  • Page 12: Care And Maintenance

    5 Care and maintenance If the filling pressure is lower than 0.8 bar (0.08 MPa), top up the heating 5.1 Caring for the product installation (→ Section 5.4.2). ▶ Clean the casing with a damp cloth and Note a little solvent-free soap. ▶...
  • Page 13: Checking The Condensate Discharge Pipe And Tundish

    ▶ If fault codes (F.XXX), LHM codes Validity: Product without filling device (N.XXX) are shown in the display or ▶ Ask your competent person where the faults occur, proceed in accordance filling tap is located. with the tables in the appendix. ▶...
  • Page 14: Permanently Decommissioning The Product

    Mūsų klientų aptarnavimo tarnybos kon- Open the cold-water isolation valve. taktinius duomenis rasite galiniame pus- lapyje nurodytu adresu arba puslapyje 9 Recycling and disposal www.protherm.eu. ▶ The competent person who installed your product is responsible for the dis- posal of the packaging.
  • Page 15: Appendix

    Appendix A Fault codes Note The code table only shows an extract of the entire code. Code/meaning Possible cause Measure F.022 Water deficiency in Check the filling pressure of the heating the heating installation installation. (→ Section 5.4.1) No/insufficient water in the product or the Top up the water in the heating installa- water pressure is too...
  • Page 16 Supplier Vaillant Group International GmbH Berghauser Strasse 40 D-42859 Remscheid Tel. +49 2191 18 0 www.protherm.eu 0020292750_02 Publisher/manufacturer Protherm Production s.r.o. Jurkovičova 45 Skalica 90901 Tel. 034 6966101 Fax 034 6966111 Zákaznícka linka 034 6966166 www.protherm.sk © These instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only with the manufacturer's written consent.