1.Caution • Electricity is strictly prohibited during installation and wiring. Please note: Any energized connection may cause accidental damage to the equipment, and we will not provide a normal warranty for damage caused by such operation. • In a place with severe static electricity or in winter, connect the ground cable before other cables to prevent transient static electricity from damaging the device, and then connect the power cable.
4. Device Installation Mounting on the Wall through Asian Gang Box ① Install the Asian gang box (or single gang box, mullion mount ) into the wall. ② Fix the back plate onto the Asian gang box (or single gang box, mullion mount using two wall mounting screws.
5. Terminal Block Power Black Green Wiegand White GLED Grey Indicator None Buzzer BEEPER Purple None None None 485A Pink RS485 485B Blue Black 6. Power Connection AC Adapter DC12V, 1A GLED Notes: BEEPER 485A Ÿ Recommended AC adapter : 12V 1A. 485B Ÿ...
7.Controller Connection This ProlD104 reader can be connected to the controller and set by software to achieve the function. The following is an example of the connection to InBio Pro controller. Connect the Controller via RS485 TCP/IP +12V 485- 485+ 485A 485B DC12V...
Page 7
Connect the Controller via Wiegand TCP/IP GLED BEEPER 485A ProID104 485B InBio Pro 8. Operating Instruction Press *# to enter the setting mode and input the administrator password (1234 by default). After entering the setting mode, the indicator will turn green.
Page 8
2. Set the Wiegand Output Mode →8→5→0/1/2/3→# Press *#→ Input the administrator password 0: Wiegand 26, 1: Wiegand 34(default), 2: reserved, 3: Wiegand 66. 3. Set the Reader Address →8→6→1~32→# Press *#→ Input the administrator password Set the reader 485 address. The value ranges from 1 to 32. 4.