Set Meter Reading Of Flow Channels - HWM COMLog 2 IS Quick Start Manual

Table of Contents

Advertisement

The channels summary shows
the presence of the newly
added channel and a combo
being set to trigger in the new
channel.
A summary of the
tamper alarm combo
is shown opposite
and can be used to
check if the combo
has already been set.
6 S
M
ET
ETER
1. Set logger with current Meter Reading.
The logger tracks the volume of gas passing through the meter (from the pulses) and sends
a meter reading into DataGate when it calls in with the flow measurements data.
Initially, the logger has not had the meter value set.
Tap on "Metering Settings".
Find the units the meter is displaying. For the meter in the example we are
using, the dial clearly states "m
The "Meter Factor" must next be determined and entered.
Unit of volume measurement used on the Meter for each digit
Meter factor =
In our example: The flow channel was set up in m
The ratio would be 1 m
Set "Meter Factor" equal to "1".
Example 2:
If the flow channel measured in ft
the meter measures in 100s of ft
the ratio would be 100 ft
Set "Meter Factor" equal to "100".
R
F
EADING OF
LOW
3
" (see diagram opposite).
Unit of volume measurement used on the Flow channel
3
/ 1 m
3
/ 1 ft
C
(
)
HANNEL
S
3
and the meter similarly measures in m
3
;
3
, whilst
3
,
3
;
11
3
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COMLog 2 IS and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents