Unit 6: Maintenance
LABEL SENSOR POSITIONING
The label sensor assembly provides a mounting apparatus for the eye-mark, gap, and paper-end sensors. Position
adjustment of the label sensor is not required when using standard label media.
When non-standard media is used, place a section of the media on the media ramp oriented as if loaded for
printing. Manually grasp the sensor assembly and move it laterally so that the sensor indicators embossed in its
side are aligned with the reference marks on the media.
Sensor positioning may also be achieved by measuring from the printer's center frame outward to a specified
distance for sensor/reference mark alignment.
Label Sensor
Print Head Latch
Adjustment Knob
Figure 6-8, Label Sensor Positioning
6-9
Lt408 Operator Manual
PN: 9001152A