Page 88
2. This command must be sent as an independent data stream
immediately following the <ESC>A Start code and immediately
preceding the <ESC>Z Stop code. No other commands can be
included in the data stream.
3. If more or less than nine commas are included in the command, the
entire command sequence will be ignored. The command must
contain exactly nine commas.
4. If two characters are specified for a parameter, it will be interpreted
as a hex value. For example:
Command Parameter
2B
+
If a combination of characters are outside the hexadecimal range,
the entire command sequence will be ignored.
5. The current protocol command codes may be verified by printing a
self test label (<ESC>CT).