22

Connecting to the IntelliTouch Load Center

To connect the four wire cable from the IntelliChlor Power Center to the Personality board located in the
IntelliTouch Load Center:
WARNING Switch OFF main system power to the Load Center before making any connections.
1. Unlatch the Load Center enclosure door spring latches, and open the door.
2. Loosen the two retaining screws from the Outdoor Control Panel.
3. Lower down the Outdoor Control Panel on its hinges to access the Personality board located behind
the Outdoor Control Panel.
Personality board
Route wire from
IntelliChlor into
conduit knockout up
through raceway to
Personality board
IntelliChlor User's Guide
Retaining screws
IntelliTouch Load Center
Outdoor Control Panel