FOR USE WITH INTELLILCHLOR CHLORINE GENERATOR
MODEL IC20, IC40 & IC60
INSTALLATION AND USER'S GUIDE
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
®
INTELLICHLOR
Salt Chlorinator Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for Pentair INTELLICHLOR IC20

  • Page 1 Power-center-manual-5209590 http://waterheatertimer.org/How-to-control-intellichlor.html ® INTELLICHLOR POWER CENTER FOR USE WITH INTELLILCHLOR CHLORINE GENERATOR MODEL IC20, IC40 & IC60 INSTALLATION AND USER’S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ® INTELLICHLOR Salt Chlorinator Installation Guide...
  • Page 2: Table Of Contents

    Technical Support Sanford, North Carolina (8 A.M. to 4:30 P.M. ET) Moorpark, California (8 A.M. to 4:30 P.M. PT) Phone: (800) 831-7133 Fax (800) 284-4151 Web sites: visit www.pentairpool.com and staritepool.com Contents IMPORTANT SAFETY PRECAUTIONS ............i IntelliChlor Power Center Overview ..............1 IntelliChlor System Components ..............
  • Page 3 IMPORTANT WARNINGS AND SAFETY INSTRUCTIONS SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT IS NOT INSTALLED AND USED CORRECTLY. INSTALLERS AND POOL OPERATORS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PUMP AND SAND FILTER. To reduce the risk of injury, service should only be done by a qualified pool service professional.
  • Page 4 IMPORTANT WARNINGS AND SAFETY INSTRUCTIONS ® Never operate the IntelliChlor Salt Chlorinator without proper flow or water circulation. A build-up of flammable gases will result in hazardous conditions. Operate unit with minimum flow of 25 gpm. For high flow applications, use a bypass loop. Only use pipe couplings that meet Schedule 80, maximum pressure 150 psi at 70°...
  • Page 5 IMPORTANT WARNINGS AND SAFETY INSTRUCTIONS For information about the Virginia Graeme Baker Pool and Spa Safety Act, contact the Consumer Product Safety Commission at (301) 504- 7908 or visit www.cpsc.gov. NOTE: Always turn off all power to the pool pump before installing the cover or working on any suction outlet.
  • Page 6 IntelliChlor Salt Chlorinator Power Center Overview ® The IntelliChlor Salt Chlorinator system comprises of a Power Center and electrolytic Cell. The Power Center converts AC electrical current to a low voltage DC current required by the IntelliChlor Salt Chlorinator electrolytic cell to operate and create chlorine for the swimming pool and spa.
  • Page 7: Operating Instructions

    IntelliChlor Salt Chlorinator System Components ® An IntelliChlor Salt Chlorinator system consists of one or more of the following: • PC100 (P/N 520556): Power Center Kit. Provides power and control communication to and from the IntelliChlor cell. • IC20 Cell (P/N 520554): Designed for pools up to 20,000 U.S. gallons (75,000 liters). The cell will produce the equivalent of 0.70 lbs.
  • Page 8 Installing the IntelliChlor Salt Chlorinator Power Center ® IMPORTANT SAFETY PRECAUTIONS. PLEASE READ THE FOLLOWING: Read all the safety precautions in this manual before attempting any electrical wiring. Be sure to read and follow all safety Instructions on page ii. Wiring should only be performed by a qualified professional.
  • Page 9: Installing The Power Center

    Installing the Power Center Install the Power Center at eye level as close to the IntelliChlor pump and filtration as possible. CAUTION: The Power Center must be installed more than 8 ft (2.44 m) from the pool edges. Leave sufficient clearance on all sides of the Power Center. Ensure that the 15 ft (4.57 m) “Type Z”...
  • Page 10 ® Connect AC Power to the IntelliChlor Power Center Note: This Power Center is wired as an “All Pole Disconnect” System . Therefore a 3 mm spacing is required for all AC wiring entering the unit. Use 12-14 AWG three conductor insulated wire for the main AC power connection.
  • Page 11: Troubleshooting

    Troubleshooting Note: Turn off power to unit before attempting to service or repair. l l e g i l y f i v i t y f i Electrical Specifications Circuit Protection: Two-pole 20 AMP device at the electrical panel. IntelliChlor Salt Chlorinator Model IC20 Input: 90-130 VAC, 50/60 Hz, 220 Watts (2 AMP) or 220-240 VAC, 50/60 Hz, 220 Watts (1 AMP).
  • Page 12: 230 Vac Basic System Wiring

    110 VAC and 220 VAC Transformer Wiring 115 VAC Basic System Wiring 230 VAC Basic System Wiring ® INTELLICHLOR Salt Chlorinator Installation Guide...
  • Page 13 IntelliChlor Salt Chlorinator SPower Center 230 VAC and 115 VAC Transformer Wiring ® INTELLICHLOR Salt Chlorinator Installation Guide...
  • Page 14: Intelllichlor Power Center With Orp Controller

    IntellliChlor Power Center with ORP Controller Connect AC Power Wires and ORP Controller Wires 1. Provide 208-260VAC power to the POWER CENTER. This power should be on its own breaker for future servicing. A knock-out opening is provided on the bottom of the power center for a conduit.
  • Page 15 System Diagram Note: For best flow sensing, provide at least 12 - 18 inches of straight pipe in front of the CELL INLET Troubleshooting Problem: The IntelliChlor 100% light does NOT come on when the ORP controller calls for chlorine Actions: 1.