Omron Promi-SD 205-OA User Manual page 35

Bluetooth rs232c serial adapter
Hide thumbs Also See for Promi-SD 205-OA:
Table of Contents

Advertisement

Promi-SD User Manual – Appendix A. AT Commands
Command Description
1 ATZ
SD Response
Purpose
Description
Reference
2 AT&F
SD Response
Purpose
Description
Reference
3 AT
SD Response
Purpose
Description
Reference
4 AT+UARTCONFIG,Baudrate,Parity,Stopbit
SD Response
Purpose
Parameters
Description
Reference
Example
5 AT+USEDIP?
 OK
Software Reset
This is the same effect as power off and on.
This command disconnects Bluetooth device, and stops ongoing task. After rebooting,
the status is decided by the preset operation mode.
Some AT commands need ATZ to take effect.
AT&F, AT+BTCSD, AT+UARTCONFIG
 OK
Hardware reset
This is the same effect as initialization by reset button.
All parameters are initialized to factory defaults. The storage of Promi-SD is cleared
completely.
ATZ
 OK
Check the connection status with host equipment
Check if the connection to host equipment is normal. The serial parameters of Promi-SD
must be same as those of host equipment. If not, SD response is none or 'ERROR' or
abnormal sequence of strings.
AT+UARTCONFIG, ATZ, AT&F
 OK
Set Serial parameters
Baudrate=1200/2400/9600/14400/19200/38400/57600/115200/230400 (Default=9600)
Parity=N/E/O (Default=N)
Stopbit=1/2 (Default=1)
Hwfc = use dipswitch.
The Serial parameters can be set or changed. The factory default is 9600, N, 1.
To take effect of this command, ATZ or power off and on.
AT, ATZ, AT&F, ATS
AT+UARTCONFIG,9600,N,1
Copyright © 2006 Sena Technologies, Inc. All rights reserved.
A-4

Advertisement

Table of Contents
loading