Replacement Parts List; Battery Selection - Zoeller Basement Sentry 507 Installation Manual

12 volt dc battery backup pump
Hide thumbs Also See for Basement Sentry 507:
Table of Contents

Advertisement

7. Alarm sounds during battery recharge cycle.
(a) Push alarm reset (max. 3 times). If condition persists, replace battery.
The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure. The
DC pump, electronic controls and all the parts required for installation are included except the battery which is supplied by the user. The system
is designed for installation in sumps with minimum of 18" diameter and 24" deep. For 18" x 22" applications, consult factory.
ITEM
DESCRIPTION
1
DC backup pump
2
Plastic battery box and cover
3
DC control charger with terminals
4
"Off"/"On" float switch
5
1½" x 5" long PVC pipe nipple
6
Check valve
7
Reducer hose coupling and clamp
8
1¼" x 1" PVC reducer fitting
9
1" pipe to hose adapter elbow
10
1" hose coupling and two clamps
11
1½" PVC pipe tee
12
1½" 90 degree PVC pipe elbow
13
1¼" x 1¼" PVC coupling
Pump mounting kit, includes brkt, S.S. worm drive
14
clamp, two #10-24 screws and washers.
15
Cable tie
16
Anchors, wall
17
Bracket, control mounting
18
1½" x 1½" PVC coupling
19
Clamp, H28 SS / zinc-plated screw
20
Fuse, AGC - 15 amp
4
1
11
6
2
12 VOLT BATTERY
SUPPLIED BY USER
TROUBLESHOOTING INFORMATION, continued
DESCRIPTION

REPLACEMENT PARTS LIST

(2) REV C - (1) REV D
19
20
3
© Copyright 2013 Zoeller Co. All rights reserved.
(b) To silence alarm if alarm will not reset, unplug the charger from
115V wall outlet, then disconnect the black lead from charger on
negative (-) battery post. Check battery. Replace if necessary.
Reconnect and refer to Installation (step 12).
MODELS:
507-C
4/96
QTY
thru
10/05
1
010475
1
10-0764
1
152899
1
017197
1
005639
005636
1
30-0188
1
005642
1
005643
1
005703
1
005645
1
005644
1
009129
1
005704
1
005868
2
009691
1
007779
1
N/A
1
012724
1
N/A

BATTERY SELECTION

The DC emergency pump system requires a good quality, 12 volt
battery to obtain maximum pumping time during a power outage.
A deep-cycle, 12 volt, 105 amp-hour marine battery or larger is
recommended and will provide approximately 7½ hours of continuous
pumping time in a sump pump installation with 8' of head pressure. In
most installations the pump runs intermittently and the battery life is
extended accordingly. Batteries with top terminals are recommended
for ease of installation. These batteries contain acid and proper
precaution must be taken when handling. Maximum battery size
13½" length x 7" width x 9½" height.
SK2981
3
507-D
507-E
11/05
10/11
thru
thru
9/11
10/13
Current
017198
017198
017198
10-0764
10-0764
10-0764
152899
152899
152899
017197
017197
017197
N/A
N/A
005636
019768
019768
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
005645
005645
005645
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
009691
009691
007779
007779
009746
N/A
012724
012724
012724
012352
012352
012352
507-F
11/13
thru
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Basement sentry series