Zoeller AQUANOT 508 Fit Installation Instructions Manual

Zoeller AQUANOT 508 Fit Installation Instructions Manual

12 volt dc battery backup pump
Hide thumbs Also See for AQUANOT 508 Fit:

Advertisement

Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
US Patent No.
D740,329
PREINSTALLATION CHECKLIST
1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer
before using.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be
retained for future reference.
1. Testing for ground. As a safety measure each electrical outlet
should be checked for ground using an Underwriters Laboratory
listed circuit analyzer, which will indicate if the power, neutral and
ground wires are correctly connected to your outlet. If they are not,
call a qualified, licensed electrician.
2. For your protection, always disconnect the power supply from its
power source before handling the components of your DC backup
pump or the primary pump.
3. Installation and servicing of electrical circuits and hardware should
be performed by a qualified, licensed electrician.
4. All electrical and safety codes must be followed including the
National Electrical Code and all applicable local codes.
5.
It is the owner's responsibility to check the battery and
battery connection at least once a month. Batteries
contain acid, and caution must be taken when handling.
6. Risk of electric shock. These pumps have not been investigated for
use in swimming pools and marine areas.
7. Prop 65 Warning for California residents: Cancer and Reproductive
Harm- www.P65Warning.ca.gov.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
12 VOLT DC BATTERY BACKUP PUMP
INSTALLATION INSTRUCTIONS
SEE BELOW FOR
LIST OF WARNINGS
© Copyright 2020 Zoeller
Real Time Peace of Mind.™
CAUTION
1. Make sure there is a properly grounded 115 V receptacle available.
Do not use primary pump circuit. The location must be within 6'
(1.8 m) of the control box and battery. The power supply for your
DC control system plugs directly into the 115 V outlet. DO NOT USE
AN EXTENSION CORD.
2. Make sure the 115 V electrical supply circuit is equipped with
fuses or circuit breakers of proper capacity.
3. DC emergency pumps are designed for handling clear water. Do
not use in septic tanks to pump effluent or in sewage pits to pump
sewage.
4. Repair and service of your DC backup system should be performed
by an authorized service station.
5. The installation of DC automatic backup pumps requires the use of
a variable level float switch for operation. It is the responsibility of
the installing party to ensure that the float switch will not hang up
on the pump apparatus or pit peculiarities and is secured so the
pump will turn "on" and "off". It is recommended that the pit be
18" (45.7 cm) in diameter or larger to accommodate both a primary
and a DC backup pump.
6. For indoor use only.
CAUTION
water can cause sump pumps to airlock. If this condition exists,
the incoming water must be baffled to avoid excessive turbulence.
Co. All rights reserved.
®
Visit our website:
zoellerpumps.com
SEE BELOW FOR
LIST OF CAUTIONS
Turbulence caused by high-velocity incoming
REFER TO WARRANTY ON PAGE 2.
FM3120
1120
Supersedes
1020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AQUANOT 508 Fit and is the answer not in the manual?

Questions and answers

Summary of Contents for Zoeller AQUANOT 508 Fit

  • Page 1 Harm- www.P65Warning.ca.gov. 6. For indoor use only. Turbulence caused by high-velocity incoming CAUTION water can cause sump pumps to airlock. If this condition exists, the incoming water must be baffled to avoid excessive turbulence. REFER TO WARRANTY ON PAGE 2. © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 2: Limited Warranty

    3 years from date of purchase by the end user. Zoeller batteries with our products.
  • Page 3: Installation

    Fit Controller is designed for use with Z Control ® ® switches as seen in Figure 1. The top rubber stop is not needed unless the "on" level needs to be lowered. 10. Install the operational float switch bracket above the "on" level of the © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 4: Initial Start-Up And Operation

    Upon release of the float switch, the pump spray out of the pump's 1/8" (3 mm) air relief hole. will shut off. Be certain there are no obstructions around the float or stem that will prevent the switch from turning off. © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 5 DC PUMP 30 AMP FUSE HIGH WATER BLACK LEAD TO NEGATIVE REED SENSOR 12 VOLT BATTERY WHITE LEAD TO POSITIVE SUPPLIED BY USER BATTERY BOX SK3185 To minimize risk of air lock, intake of DC pump must be set above intake of primary pump. IMPORTANT © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 6 DC pump (Yellow)* Pump Fault (Red) High Water (Red) Float Fault (Red) Float Status Connected Searching Broadcasting SSID or Dormant Z Control * Note: will not persist if pump didn’t pump water. See also the laminated label affixed to the controller’s cord. This cord label also describes LED and button functionality. © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 7: Maintenance

    If the signal is questionable, your network may not be able to provide a stable connection for the Fit. • Verify your WiFi network is connected to the internet and that it is broadcasting a visible, secure, 2.4Ghz network. © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 8 Device ID. When user is connected to Fit to set up WiFi, LED will blink. When Fit is connected to router and Z Control Cloud, ® this LED will be solid. © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 9 Fit will connect to the network and start sending status updates to zcontrolcloud.com. You will see the Z Control LED go from blinking to solid. This could take up to a minute or so. ® If the LED does not turn solid, then the passphrase entered is incorrect, the router’s security is insufficient (see note below**), or some other network restriction is in place (see your network administrator). The Fit will return to standby mode if the connection to router is not successful. If you need to force the Fit into AP mode again, press the Z Control button for 12 seconds (See Figure A). This will cause the ® Fit to re-enter AP mode and begin transmitting its SSID again. Repeat Steps 2 and 3. © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 10 Cloud. If an update is taking place, the Z Control LED will flicker for up to 1 minute while the update is downloaded. The Z Control ® ® ® LED will be solid and all other LEDs will turn off while the update is being installed. After up to 1 minute, the Fit will restart and return to normal operation. The Fit’s alert history on the Z Control Cloud will also be updated with the firmware upgrade information, and nofication to email ® accounts will occur. Figure D Select Add New Device When you add the correct Device ID, a Fit product tile will appear in your account © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 11: Carbon Monoxide Detectors

    There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never become fully charged and may damage the charging circuits of the controller. It is for this reason that Zoeller offers its own line of batteries.
  • Page 12 MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 Visit our website: (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 zoellerpumps.com © Copyright 2020 Zoeller Co. All rights reserved. ®...

Table of Contents