Zoeller Aquanot Spin 508 Technical Data Sheet

Zoeller Aquanot Spin 508 Technical Data Sheet

Submersible sump pump system

Advertisement

Quick Links

Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Patent No. D740329

CONTROLLER

The Aquanot
Spin 508 is a premium high performance, self-testing
®
battery backup pump system.

PUMP

12 volt, highly efficient, non-corrodible pump construction
supplied with 9' (2.7 m) leads
Legs allow free-standing installation
Quick disconnect discharge
Aluminum seal pocket and cooling plate
Integrated check valve
CONTROLLER
The Aquanot
®
Spin DC Controller keeps the battery charged. The
controller has many built-in features such as:
Monitors the switches, runs the pump
Performs self-testing diagnostics
Uses multi-stage charging for optimal battery condition

ALERTS

Pump cycled
High water*
Battery fault
Switch fault
Pump fault

BUTTONS

Alarm Silence/Reset - press to silence alarms. Press and hold
for three seconds to reset alarms.
Test - press to initiate pump test

SWITCHES

Reliable, vertical float switch for adjustable operation.
High water reed sensor sold separately. P/N: 10-4830. Reed
sensor provides high water signal and redundant pump run.

BATTERY CASE

The included battery case will accommodate maximum battery
dimensions of 13" (330 mm) L x 7-1/2" (191 mm) W x 9-1/2" (241
mm) H and fits all group size 27, 29 and 31 batteries. Made from
non-corrodible polyethylene. To use multiple batteries, order extra
battery case with hookup wire (P/N 10-5184).

FITTINGS

An integrated DC pump discharge check valve, additional thread-in
AC pump check valve, tee, and adapter are included.
502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | zoellerpumps.com
TECHNICAL DATA SHEET
MODEL 508 12-VOLT BACKUP
Submersible Sump Pump System
Power outage/restored
Pump activation
© Copyright 2022 Zoeller
AQUANOT
Solid
System
No Faults (Green)
Ready
Charged (Green)
Battery
Charging (Yellow)
Bad Battery (Red)
Pump Ran
DC pump
(Yellow)
Float
High Water
Status
(Red)*
* If optional high water reed sensor is being used
Aquanot ® Spin 508 system
Aquanot ® Deep-Cycle Battery (purchase separately)
P/N 10-1450 - AGM (shown)
P/N 10-0761 - Wet
P/N 10-5105 - Wet
Co. All rights reserved.
®
SECTION: 2.65.014
Supersedes
SPIN
®
Flashing
Off
AC off with no
--
faults (Green)
Low Battery (Red)
No AC Power
Pump Running
(Yellow)
--
Pump Fault (Red)
Float Fault (Red)
--
FM3165
0422
0320

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aquanot Spin 508 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zoeller Aquanot Spin 508

  • Page 1 Aquanot ® Deep-Cycle Battery (purchase separately) P/N 10-1450 - AGM (shown) P/N 10-0761 - Wet P/N 10-5105 - Wet © Copyright 2022 Zoeller Co. All rights reserved. ® 502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | zoellerpumps.com...
  • Page 2 All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be CAUTION followed including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). © Copyright 2022 Zoeller Co. All rights reserved. ®...

This manual is also suitable for:

Aquanot spin 508/m53 propakAquanot spin 508/m98 propak508-0005508-0006508-0007

Table of Contents