Fit the indoor device to the hook at the top of the
mounting plate and let it lock into place at the
bottom.
The package of lines/hoses is to be laid between
the housing of the indoor device and the wall. In
order to prevent condensation water, insulate the
package of lines/hoses with heat insulation
material.
Fit the two halves of the inside wall hole cap to
the wall hole tube.
Hook at the top
Hook at the
bottom
Wall hole cap
4. Installing the outdoor device
It is imperative that you follow the installation
instructions.
4.1 Before you start installation
Select the location for installation (follow the
previous notes on selecting the location).
Check that the available mains voltage is the
same as the voltage specified on the rating plate.
The maximum distance between the indoor and
the outdoor device is restricted by the length of
the coolant tube, which is a maximum of 4m. It is
NOT possible to extend the coolant tube.
If the outdoor device is higher than the indoor
device, make sure that a curve is made in the
coolant tube which is lower than the bottom edge
of the indoor device.
Fasten the condensation water drain to the base
of the outdoor device.
Outddor device
Coolant tube
Inddor device
Curve
07.12.2006
14:09 Uhr
4.2 Mounting the outdoor device
The outdoor device can be fastened to the
ground or to a wall bracket (e.g. special
accessory Art. No. 23.651.55) with dowels and
screws. To do so, use the holes on the device.
5. Connecting the refrigerant lines
5.1 Important information
-You will require the following tools to carry out this
installation work correctly:
1x open-ended spanner, 19 mm
Heat insulation
1x open-ended spanner, 22 mm
material
1x open-ended spanner, 24 mm
1x Allen key, 5 mm
1x Philips screwdriver
1x leak detection spray or alternatively soap suds
(water / detergent mix)
Follow the detailed instructions for connecting
the refrigerant lines to the letter. We can only
provide a warranty if the lines are installed
correctly as described in the instructions.
Kinked and/or damaged lines and connectors
can only be accepted under the warranty if a
claim is made for them before the installation
work is carried out.
Do not remove the sealing caps and stoppers
until immediately before you install the lines.
To prevent leaks, ensure that the quick-release
screw connections are absolutely free of dirt.
Moisture or foreign bodies will adversely affect
the function of the quick-release connectors,
leading to a risk of refrigerant loss (not covered
by the warranty).
Only install refrigerant lines outdoors in dry
weather.
The refrigerant lines must not be installed and
then plastered over.
Please make sure that refrigerant is never
allowed to enter the environment.
Improper handling of refrigerant may be harmful
to health. Always wear work gloves and goggles
when handling refrigerant.
The equipment designed for outdoor use may
only be installed outdoors. Provide good
ventilation.
Do not smoke during the installation work.
The equipment must never be operated without
the refrigerant lines connected, otherwise the
equipment will be damaged immediately.
The screw connections may only be tightened
using the appropriate open-ended spanner.
Remember that if they are tightened with too little
torque they will leak but if they are tightened with
Seite 25