Important note:
This high-quality product will only offer optimum service
if installed correctly and in the right place, and is put into
operation for the first time by a suitably competent
person.
Avoid malfunctions by seeking competent advice from
an expert with regards to the location, installation and
starting up of the system.
We shall accept no liability for malfunctions or
inadequate cooling performance resulting from the
improper handling of the product.
In accordance with national legislation based on EU
Regulation 303/2008, every intervention in the
refrigerating circuit - including all connection activities -
may only be carried out by an air-conditioning specialist.
For this reason the DIY installation of refrigerant lines for
this air conditioner may no longer be carried out by
unskilled workers.
The 230 V socket-outlet required to supply power must
be connected and commissioned by a specialist
contractor.
If the system is to be moved to another location or
disposed of, only a suitably qualified
electricianʼs/cooling system firm is permitted to
undertake any work of disassembly or disposal.
Art.-Nr.: 23.657.16
Art.-Nr.: 23.657.36
10.12.2008
11:53 Uhr
Seite 1
Split 2500 EQ C+H
I.-Nr.: 01017
Split 3500 EQ C+H
I.-Nr.: 01017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Split 3500 EQ C+H and is the answer not in the manual?

Questions and answers

Summary of Contents for EINHELL Split 3500 EQ C+H

  • Page 1 If the system is to be moved to another location or disposed of, only a suitably qualified electricianʼs/cooling system firm is permitted to undertake any work of disassembly or disposal. Split 2500 EQ C+H Art.-Nr.: 23.657.16 I.-Nr.: 01017 Split 3500 EQ C+H Art.-Nr.: 23.657.36 I.-Nr.: 01017...
  • Page 2 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:53 Uhr Seite 2...
  • Page 3 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:53 Uhr Seite 3...
  • Page 4 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:53 Uhr Seite 4...
  • Page 5 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 5 A =780 mm...
  • Page 6 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 6...
  • Page 7 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 7...
  • Page 8 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 8...
  • Page 9 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 9...
  • Page 10: Table Of Contents

    Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 10 Table of contents 1. Safety regulations 2. Items supplied 3. Technical data 4. Intended use 5. Description of parts 6. Display - Indoor device 7. Setting up the remote control 8. Description of the remote control functions 9.
  • Page 11: Safety Regulations

    Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 11 Never use combustible cleaning agents as these Important! could cause a fire or deformation. When using the equipment, a few safety precautions If the air conditioner is to be used in conjunction must be observed to avoid injuries and damage. with other heaters, the air should be refreshed Please read the complete operating instructions and periodically, otherwise there is a risk of lack of...
  • Page 12: Items Supplied

    1 indoor device (box 1, art. no. 23.654.18) 1 outdoor device (box 2, art. no. 23.654.19) Weight Outside 28 kg 1 set of installation accessories (for details, see page Split 3500 EQ C+H 1 indoor device (box 1, art. no. 23.654.36)
  • Page 13: Intended Use

    Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 13 Split 3500 EQ C+H Heating: Air temperature at the inlet on the indoor device: Cooling capacity 3300 watts 20°C for dry thermometer bulb (DB), 15°C for wet Heating capacity 3600 watts thermometer bulb (WB). Outdoor air temperature: Energy efficiency B (EER 3.14/COP 3.42)
  • Page 14: Description Of Parts

    Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 14 manufacturer will be liable for any damage or injuries Notes of any kind caused as a result of this. The radio signal has a range of approx. 8 m. Use two alkali batteries, type R03 AAA (1.5 V). Please note that our equipment has not been Always replace both batteries at once when you designed for use in commercial, trade or industrial...
  • Page 15 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 15 reactivate the display. area. If a deactivation time has been selected, 8. FAN SPEED: Pressing this button enables you TIMER OFF will be displayed. If both functions to select the fan speed. Each time you press this have been selected, TIMER OFF will be button the speed will be switched in the following...
  • Page 16: Indoor Device Settings

    Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 16 C) DRY (dehumidifier) mode 9. Indoor device settings 1. Press the MODE button to select DRY mode. 2. Pressing the TEMP buttons enables you to Remote control fails to work (emergency select the required room temperature. The operation) (Fig.
  • Page 17: Cleaning Notes

    Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 17 Notes: Cleaning the air filters of the indoor device 1. If the air conditioning system is not switched on Make sure that the air filters are clean! Soiled air or TIMER ON is active, the AIR DIRECTION and filters reduce the air output of the device.
  • Page 18: General Notes

    Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 18 11. General notes the room is also high. “white mist” may be generated in cool mode. b) If the air conditioning system is restarted in heat Restarting after lengthy non-use mode after de-icing, “white mist” may be If the air-conditioning system has not been used for a generated by moisture in certain circumstances.
  • Page 19: Troubleshooting

    Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 19 system being unable to achieve an adequate room Please contact our service partner immediately if temperature. Please note that the heat function is the following fault codes are displayed only really suitable for use during autumn and spring. Display E1 9.
  • Page 20: Installation Accessories

    Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 20 13. Installation accessories distance of at least 3 mm (e.g. circuit-breaker). Connect the electrical connections of the indoor and outdoor devices together first and then connect to Please check that all the installation accessories the mains power supply.
  • Page 21 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 21 expected snow line. Snow must not be allowed immediately before you connect them. to get into the outdoor unit. Open refrigerant lines must be protected from 8. The wall for installation must be strong and the ingress of moisture by suitable caps or capable of supporting the weight of the unit.
  • Page 22 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 22 5. Connecting the refrigerant lines yourself, it is imperative that you contact your customer service team or a refrigeration contractor. 5.1 Important information Important! The EQ valves are only designed for one-time installation. Their seal cannot be -You will require the following tools to carry out this guaranteed if they are installed on more than one installation work correctly:...
  • Page 23 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 23 This will also void the warranty. C. Mounting the outdoor device After completing steps 1 – 3, check that all the It is imperative that you follow the installation connections are sealed correctly using leak detection instructions.
  • Page 24 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 24 refrigerant line until immediately before you Fig. 37-39: Now remove the cover on the bottom connect them. The mating connections are valve using a 19 mm open-ended spanner. Open marked with identical letters. the valve by turning it counter-clockwise as far as Fig.
  • Page 25: Ordering Replacement Parts

    Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 25 sources of heat. Check that the + and – terminals on the batteries are positioned correctly in the remote control. Fasten the remote control holder to the wall with dowels and screws. 6. Self-adhesive foils for indoor device The device is supplied with two self-adhesive foils for the exclusive color design of the indoor unit of your air-conditioner.
  • Page 26 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 26 Konformitätserklärung ISC-GmbH · Eschenstraße 6 · D-94405 Landau/Isar erklärt folgende Konformität gemäß EU-Richtlinie dichiara la seguente conformità secondo la und Normen für Artikel direttiva UE e le norme per lʼarticolo declares conformity with the EU Directive attesterer følgende overensstemmelse i and standards marked below for the article henhold til EU-direktiv og standarder for produkt...
  • Page 27 Samræmisyfirl‡sing sta›festir eftirfarandi samræmi mas∂n∂ sunar. samkvæmt reglum Evfrópubandalagsins og stö›lum ‰ËÏÒÓÂÈ ÙËÓ ·ÎfiÏÔ˘ıË Û˘Ìʈӛ· Û‡Ìʈӷ Ì fyrir vörur ÙËÓ √‰ËÁ›· ∂∂ Î·È Ù· ÚfiÙ˘Ô ÁÈ· ÙÔ ÚÔ˚fiÓ Split Klimaanlage Split 3500 EQ C+H 98/37/EG 87/404/EWG 2006/95/EG R&TTED 1999/5/EG 97/23/EG...
  • Page 28 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 28 The reprinting or reproduction by any other means, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of ISC GmbH. Technical changes subject to change...
  • Page 29 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 29 t For EU countries only Never place any electric tools in your household refuse. To comply with European Directive 2002/96/EC concerning old electric and electronic equipment and its implementation in national laws, old electric tools have to be separated from other waste and disposed of in an environment-friendly fashion, e.g.
  • Page 30 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 30...
  • Page 31 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 31...
  • Page 32 Anleitung_Split_2500-3500_EQ_C_H_GB:_ 10.12.2008 11:54 Uhr Seite 32 t GUARANTEE CERTIFICATE Dear Customer, All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event that your device develops a fault, please contact our service department at the address shown on this guarantee card.