# Span 1: TE4/0/1 "T4XXP (PCI) Card 0 Span 1" (MASTER) HDB3/CCS/CRC4
ClockSource
span=1,1,0,ccs,hdb3,crc4
# termtype: te
bchan=1-15,17-31
dchan=16
#echocanceller=mg2,1-15,17-31
# Span 2: TE4/0/2 "T4XXP (PCI) Card 0 Span 2"
span=2,2,0,ccs,hdb3,crc4
# termtype: te
bchan=32-46,48-62
dchan=47
#echocanceller=mg2,32-46,48-62
# Span 3: TE4/0/3 "T4XXP (PCI) Card 0 Span 3"
span=3,3,0,ccs,hdb3,crc4
# termtype: te
bchan=63-77,79-93
dchan=78
#echocanceller=mg2,63-77,79-93
# Span 4: TE4/0/4 "T4XXP (PCI) Card 0 Span 4"
span=4,4,0,ccs,hdb3,crc4
# termtype: te
bchan=94-108,110-124
dchan=109
#echocanceller=mg2,94-108,110-124
# Global data
loadzone
defaultzone
2. Country mode modification
In order to match your country pattern, you need to change parameters
loadzone and defaultzone to your country. For example, your system is in
CHINA, you would like them change to:
loadzone = cn
defaultzone = cn
OpenVox Communication Co. LTD.
= us
= us
Figure 4 A part of system.conf
D430E/DE430E on DAHDI User Manual
URL: www.openvox.cn
21