Layout Of Appliance - Worcester benchmark ZWB 7-25 R 25 HE Design, Installation And Servicing Instructions

Table of Contents

Advertisement

Details of the appliance
1.6

Layout of appliance

221.1
221.2
27
226
20
29
271
43
9
63
358
64
7
355
6.1
88
295
417
Fig. 2
4
Heatronic control
6
Heat exchanger safety temperature limiter
Hot water NTC sensor
6.1
7
Testing point for gas supply pressure
8.1
Pressure gauge
Flue gas temperature limiter
9
15
Relief valve
18
Pump
18.1
Pump speed selector switch
20
Expansion vessel
27
Automatic air vent
29
Air gas Mixer unit
32.1
Electrode assembly
36
Temperature sensor in CH flow
43
CH flow
63
Adjustable gas flow restrictor
Adjusting screw for min. gas flow volume
64
88
3-way valve (combi)
98
DHW flow switch (combi)
6
120
102
32.1
36
6
415
416
18
423
18.1
418
15
8.1
88
4
6 720 610 599-00.TD
102
Inspection window
120
Fixing points
221.1 Flue duct
221.2 Combustion air intake
226
Fan assembly
Appliance type sticker
295
271
Flue duct
355
Plate-type domestic hot water heat exchanger
358
Condensate trap
415
Cover plate for cleaning access
416
Condensate collector
417
Clip for fixing outer case
418
Data plate
423
Siphon
6 720 611 441 GB (03.11)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Benchmark zwb 7-30 r 30 he47 311 7747 311 78

Table of Contents