Features And Controls; Assembly; Operation - Briggs & Stratton 030806 Manual

Table of Contents

Advertisement

Available languages

Available languages

Features and Controls Figure
A
Retractable Handle
B
Activate Switch
C
Low Oil Indicator
D
Hour Meter
E
QPT Button
Recoil Starter
F
G Identification Label
H
Oil Service Cover
J
Fuel Cap
K
Maintenance Cover
Choke Lever (under
L
cover)
M Battery Cover

Assembly

Connect Battery Figure
You must connect battery to generator to enable electric
or remote starting. The display panel, LED's and e-choke
system are also powered by the battery.
1. Remove screw and panel from in front of battery.
2. Connect two pin connector from battery to
generator.
Pairing Remote Start Fob to the Generator
Figure
1 3
The remote start fob needs to be paired with the
generator to remotely start your generator. To pair the
fob with the generator, follow the instructions below:
1. Press and hold the activate switch (1, B) for 10
seconds and the on/off button (1, Z) light will begin
to flash blue.
2. Within 30 seconds, press and hold either button on
the remote start fob (3) for 2 seconds. The on/off
button (1, Z) light will blink rapidly 3 times signaling
the remote start fob has been paired.
NOTICE All remote start fobs can be disconnected by
pressing both the on/off button (1, Z) and activate switch
(1, B) on the generator at the same time for 10 seconds.
N
12 Volt DC Receptacle
P
Grounding Fastener
Q 230 Volt AC, 16 Amp
Receptacles
R
Circuit Breakers
S
Carbon Monoxide
(CO) Shutdown
Indicator Light
USB Ports
T
U
Oil Drain Plug (under
cover)
V
Oil Fill/Dipstick (under
cover)
W Spark Arrester Muffler/
Exhaust
X
Fuel Valve
Main Reset
Y
Z
On/Off Button
2
Prevent Carbon Monoxide (CO) Poisoning
> 6.1 m

Operation

1
Step 1: Safe Location
Before starting the portable generator there are two
equally important safety concerns regarding carbon
monoxide poisoning and fire that must be addressed.
Operation Location to Reduce the Risk of Carbon
Monoxide Poisoning
WARNING! Engine exhaust contains carbon
monoxide, a poisonous gas that could kill you in
minutes. You cannot smell it, see it, or taste it.
Even if you do not smell exhaust fumes, you could still be
exposed to carbon monoxide gas.
• Operate portable generator only outdoors, at least 6.1 m
from occupied spaces with exhaust pointed away to
reduce the risk of carbon monoxide accumulating.
• Install battery-operated carbon monoxide alarms or
plug-in carbon monoxide alarms with battery back-up
according to the manufacturer's instructions. Smoke
alarms cannot detect carbon monoxide gas.
• Do not run portable generator inside homes, garages,
basements, crawlspaces, sheds, or other partially
enclosed spaces even if using fans or opening doors
and windows for ventilation. Carbon monoxide can
quickly build up in these spaces and can linger for
hours, even after this product has shut off.
• Always point the engine exhaust away from occupied
spaces.
If you start to feel sick, dizzy, weak, or your homes
carbon monoxide alarm sounds while using this product,
get to fresh air right away. Call emergency services. You
may have carbon monoxide poisoning.
Use outdoors at least 6.1 m from any home.
Point exhaust away from all homes and
occupied spaces.
Install CO alarms inside your home.
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P4500

Table of Contents