Page 1
ETT 1264 Multi-touch Operating Panel Operating Manual Date of creation: 16.12.2021 Version date: 28.03.2022 Article number: 01-230-1264-E...
Page 2
(print, photocopy, microfilm or in any other process) without express permission. We reserve the right to make changes in the content without notice. SIGMATEK GmbH & Co KG is not responsible for technical or printing errors in this handbook and assumes no responsibility for damages that occur through...
Page 3
ETT 1264 Multi-touch Operating Panel ETT 1264 The ETT 1264 is an intelligent panel for visualizing, operating and monitoring automated processes. Process diagnostics is therewith simplified. A projective capacitive touch screen serves as the input medium for process data and parameters.
1.2 Important Reference Documentation HW IP Address Settings This and additional documents can be downloaded from our website or obtained through support. 1.3 Contents of Delivery 1x ETT 1264 8x angle bracket 1x 4-pin Phoenix connector plug 28.03.2022 Page 5...
ETT 1264 MULTI-TOUCH OPERATING PANEL 2 Basic Safety Guidelines 2.1 Symbols Used The following symbols are used in the operator documentation for warning and danger messages, as well as informational notes. DANGER Danger indicates that death or serious injury will occur, if the specified measures are not taken.
Page 9
MULTI-TOUCH OPERATING PANEL ETT 1264 CAUTION Caution indicates that moderate to slight injury can occur, if the specified measures are not taken. To avoid moderate to slight injuries, observe the all guidelines. Attention indique une situation dangereuse qui, faute de prendre les mesures adéquates, peut entraîner des blessures assez graves ou...
Please thoroughly read the corresponding documents and this operating manual before handling a product. SIGMATEK GmbH & Co KG is not liable for damages caused through, non-compliance with these instructions or applicable regulations.
2006/42/EG guidelines is correct. As long as the machine with which the product should be used does not comply with the guideline, operating this product is prohibited. Operate the unit with devices and accessories approved by SIGMATEK only. 28.03.2022...
ETT 1264 MULTI-TOUCH OPERATING PANEL CAUTION Handle the device with care and do not drop or let fall. Prevent foreign bodies and fluids from entering the device. The device must not be opened, otherwise it could be damaged! Manipulez l’appareil avec précaution et ne le laissez pas tomber.
The product was constructed in compliance with the following European Union guidelines and tested for conformity. 3.1.1 EU Conformity Declaration EU Declaration of Conformity The product ETT 1264 conforms to the following European guidelines: 2014/35/EU Low-voltage Guideline 2014/30/EU Electromagnetic Compatibility (EMC Guideline) 2011/65/EU “Restricted use of certain hazardous substances in electrical and electronic equipment”...
ETT 1264 MULTI-TOUCH OPERATING PANEL 4 Technical Data 4.1 Performance Data Processor EDGE3-Technology Processor cores Internal program and 2-GByte (DDR4) data memory (RAM) Internal remnant data memory 128-kByte FRAM Internal storage device 8-GByte eMMC Optional memory expansion microSD Graphic integrated in EDGE processor...
MULTI-TOUCH OPERATING PANEL ETT 1264 4.2 Electrical Requirements Supply voltage +24 V DC ±20 % (SELV/PELV) UL: Class 2 of LVLC Protection class Current consumption of (+24 V) typically 500 mA maximum 760 mA power supply (with no external devices...
ETT 1264 MULTI-TOUCH OPERATING PANEL 4.3 Display Type 12.1” TFT color display Resolution WXGA 1280 x 800 pixels Color depth 18-Bit RGB LCD mode normally black LCD Polarizer transmissive Pixel size 0.2040 x 0.2040 mm Active range 261.12 x 163.20 mm...
ETT 1264 4.4 Control Unit Operating field Touch screen (multi-touch, projective capacitive) Maximum number of fingers The operation with thin gloves SIGMATEK Touch pen (passive) Handwriting recognition Ball of the thumb recognition Water spray recognition Water detection Cleaning see chapter 13.1 Cleaning and Disinfecting the Touch Screen...
ETT 1264 MULTI-TOUCH OPERATING PANEL 4.5 Minimum Distance between Operating Elements for Multi-touch Applications To guarantee smooth operation with multi-touch applications, buttons and control elements that should be operated at the same time must have a realistic minimum clearance. INFORMATION The size of the buttons and operating elements directly affect the operability of the application.
MULTI-TOUCH OPERATING PANEL ETT 1264 4.6 Input Input Multi-touch screen (PCAP) 4.7 Environmental Conditions Storage temperature -10 … +70 °C Environmental temperature 0 … +55 °C Humidity 10-95 %, non-condensing Installation altitude above sea 0-2000 m without derating level > 2000 m up to a maximum of 5000 m with derating of the maximum environmental temperature by 0.5 °C per 100 m...
By configuring the packet filter (Firewall or Router) accordingly however, it is possible to connect a network with SIGMATEK hardware to a third party network without triggering the error mentioned above.
+3V3 DAT0 DAT1 INFORMATION It is recommended that only storage media provided by SIGMATEK be used. The number of read and write actions have a significant influence on the lifespan of the storage media. The microSD card is not intended as an exchangeable medium and should therefore be removed from the card holder for maintenance purposed only.
ETT 1264 MULTI-TOUCH OPERATING PANEL 5.1.5 X7: USB Online OTG 2.0 (Type Mini-B) Function +5 V, I = 500 mA out,max 5.2 Applicable Connectors 4-pin Phoenix plug with spring terminal FMC 1.5/ 4-ST-3.5 (included with delivery) X2, X3: 8-pin RJ45 (not included with delivery)
MULTI-TOUCH OPERATING PANEL ETT 1264 5.3 Status Display LEDs Two status LEDs for diagnostics are located on the front. Symbol Image 7“ LED Green (1) LED Red (2) Status Lights - Supply voltage OK - During operating system start - Application running...
ETT 1264 MULTI-TOUCH OPERATING PANEL 6 Mechanical Dimensions Dimensions 313 x 215 x 44 mm (W x H x D) Material Housing: aluminium/steel chromated Color: black Front: glass 1.1 mm Weight 1.8 kg Page 22 28.03.2022...
MULTI-TOUCH OPERATING PANEL ETT 1264 7 Assembly/Installation 7.1 Check Contents of Delivery Ensure that the contents of the delivery are complete and intact. See chapter 1.3 Contents of Delivery. INFORMATION On receipt and before initial use, check the device for damage. If the device is damaged, contact our customer service and do not install the device in your system.
ETT 1264 MULTI-TOUCH OPERATING PANEL 7.3.1 Required Cutout for Mounting the Terminal Control cabinet cutout width X 304 mm Control cabinet cutout height Y 206 mm Maximum thickness of control 3.5 mm cabinet wall Z Page 24 28.03.2022...
MULTI-TOUCH OPERATING PANEL ETT 1264 7.3.2 Mounting Position Observe the mounting position of 60-120°. INFORMATION The specified installation distances may be reduced if appropriate measures and technical precautions are taken to dissipate the corresponding waste heat. 28.03.2022 Page 25...
ETT 1264 MULTI-TOUCH OPERATING PANEL 7.3.3 Minimum Distance Installation 110 mm 40 mm 60 mm 40 mm 40 mm With additional suitable measures for cooling, the minimum distances can be reduced. Page 26 28.03.2022...
MULTI-TOUCH OPERATING PANEL ETT 1264 8 Wiring 8.1 Grounding The device must be grounded to protective earth (PE) via the blade terminal provided. In addition, ensure that when installing into the control cabinet, a large grounding surface is provided. It is important to establish a low-Ohm connection to ground to ensure error-free function.
ETT 1264 MULTI-TOUCH OPERATING PANEL 8.3 ESD Protection CAUTION Typically, USB devices (keyboard, mouse etc.) are equipped with non- shielded cables. These devices are disrupted by ESD and in some instances, no longer function. Généralement, les périphériques USB (clavier, souris etc) ne sont pas équipés de câbles blindés.
ETT 1264 MULTI-TOUCH OPERATING PANEL 10 Status and Error Messages Status and error messages are shown in the status test of the LASAL CLASS software. POINTER or CHKSUM messages can also be shown on the screen. Number Message Definition Cause/Solution...
Page 33
MULTI-TOUCH OPERATING PANEL ETT 1264 Number Message Definition Cause/Solution An invalid checksum was Cause/Solution: s. POINTER CHKSUM detected before running the user program. WATCHDOG The program was Possible Causes: interrupted via the User program interrupts watchdog logic. blocked over a longer period of time (STI command forgotten).
Page 34
ETT 1264 MULTI-TOUCH OPERATING PANEL Number Message Definition Cause/Solution The hardware monitoring Solution: WD DEFECT circuit (watchdog logic) is Exchange CPU defective. After power-up, the CPU checks the watchdog logic function. If an error occurs during this test, the CPU deliberately...
Page 35
MULTI-TOUCH OPERATING PANEL ETT 1264 Number Message Definition Cause/Solution The CPU is in single step Info SINGLE STEP mode and is waiting for further instructions. READY: A module or project has Info been sent to the CPU and it is ready to run the program.
Page 36
OP INSTALLED The operating system Info has been reinstalled. OS TOO LONG The operating system Restart, report error to SIGMATEK. cannot be loaded; too little memory. Boot loader message, no Restart, report error to SIGMATEK. NO OPERATING SYSTEM operating system found in RAM.
Page 37
MULTI-TOUCH OPERATING PANEL ETT 1264 Number Message Definition Cause/Solution This error does not occur This error code is used in the OFFLINE in the control. programming system to show that there is no connection to the control. Reserved APPL LOAD...
Page 38
Cause/Solution An error has occurred FLOATING POINT ERROR during a floating-point operation. DIAS-RISC-ERROR Error from the Intelligent Restart, report error to SIGMATEK. DIAS Master. INTERNAL ERROR An internal error has Restart, report error to SIGMATEK. occurred, all applications are stopped.
Page 39
MULTI-TOUCH OPERATING PANEL ETT 1264 Number Message Definition Cause/Solution A connection error with Possible Causes: S-DIAS ERROR an S-DIAS module has Real network does not match occurred. the project, S-DIAS client is defective Solution: Analyze log file SRAM ERROR An error occurred while...
Page 40
ETT 1264 MULTI-TOUCH OPERATING PANEL Number Message Definition Cause/Solution An unknown object from C_UNKNOWN_CID a stand-alone or embedded object, or an unknown base class was detected. The operating system C_UNKNOWN_CONSTR class cannot be created; the operating system is probably wrong.
Page 41
MULTI-TOUCH OPERATING PANEL ETT 1264 Number Message Definition Cause/Solution Linking is complete. LINKING DONE OP BURN The operating system is currently being burned into the Flash memory. An error has occurred OP BURN FAIL while burning the operating system. OP INSTALL The operating system is currently being installed.
ETT 1264 MULTI-TOUCH OPERATING PANEL 11 Transport/Storage INFORMATION This device contains sensitive electronics. During transport and storage, high mechanical stress must therefore be avoided. For storage and transport, the same values for humidity and vibration as for operation must be maintained! Temperature and humidity fluctuations may occur during transport.
MULTI-TOUCH OPERATING PANEL ETT 1264 12 Storage INFORMATION When not in use, store the device according to the storage conditions. See chapter 11 Transport/Storage. During storage, ensure that all protective covers (if available) are placed correctly, so that no contamination, foreign bodies or fluids enter the device.
ETT 1264 MULTI-TOUCH OPERATING PANEL 13 Maintenance INFORMATION During maintenance as well as servicing, observe the safety instructions from chapter 2 Basic Safety Guidelines. Lors de l'entretien et de la maintenance, respectez les consignes de sécurité du chapitre 2 Basic Safety Guidelines.
MULTI-TOUCH OPERATING PANEL ETT 1264 WARNING If the device is contaminated with toxic or erosive chemicals, it must be carefully cleaned as quickly as possible to prevent personal injury and machine damage! Si l’appareil est contaminé par des produits chimiques toxiques ou érosifs, il doit être soigneusement nettoyé...
ETT 1264 MULTI-TOUCH OPERATING PANEL 13.3 Repair INFORMATION When sent for repair, the device should be transported in the original packaging if possible. Otherwise, packaging should be selected that sufficiently protects the product from external mechanical influences. Such as cardboard filled with air cushioning.
MULTI-TOUCH OPERATING PANEL ETT 1264 14 Buffer Battery A Lithium battery is installed at the manufacturer. The battery has enough capacity to preserve data in the absence of a supply voltage for up to circa 20 years. COMPANY DATA Lithium battery RENATA 3.0 V/235 mAh...
ETT 1264 MULTI-TOUCH OPERATING PANEL 14.1 Data Retention Battery Change The exchangeable buffer battery ensures that the following data is preserved in the absence of a supply voltage: Time If the battery is empty, the following settings are reset or data is deleted: Time (reset to default value) 14.2 Exchanging the Battery...
MULTI-TOUCH OPERATING PANEL ETT 1264 board). 7. Close the cover and tighten the locking screws (0.7 Nm). 15 Display „Burn-In“ Effect The “Burn-In” effect describes a pattern burned into the display after displaying the same contents over a longer period of time (e.g. a single screen).
Page 50
ETT 1264 MULTI-TOUCH OPERATING PANEL screen or a USB operating device. The wait time for the screen saver can be adjusted in the application via the HW class. This change is only active as long as the device is running the application, in Reset mode, the 60-minute default setting is restored.
MULTI-TOUCH OPERATING PANEL ETT 1264 16 Disposal INFORMATION Should you need to dispose of the device, the national electronic scrap regulation must be observed. The device appliance must not be disposed of as household waste. 28.03.2022 Page 49...
ETT 1264 MULTI-TOUCH OPERATING PANEL 17 Accessories 17.1 Touch Pen Description Order Number Touch pen with holder V3 01-690-059-3 17.2 Battery Description Order Number Lithium battery RENATA 01-690-055 17.3 microSD Card Description Order Number 8 Gbyte 12-630-802 Page 50 28.03.2022...
To ensure longevity of the memory, writing cyclic data to the internal storage medium should be avoided (lifespan drastically reduced). For cyclic writing, an external storage medium (e.g. microSD card or USB stick, depending on the respective device) from SIGMATEK must be used.
Page 54
ETT 1264 MULTI-TOUCH OPERATING PANEL Changes Chart Change Affected Chapter Note date page(s) 15.03.2022 5.1 Rear Connectors X1: Name and graphic corrected 5.2 Applicable Connectors 28.03.2022 4.7 Environmental Conditions Environmental Conditions changed Page 52 28.03.2022...
Need help?
Do you have a question about the ETT 1264 and is the answer not in the manual?
Questions and answers