Surface Burners; Quick Power Disconnect - Viking RVGR3305B Service Manual

30 inch gas range
Hide thumbs Also See for RVGR3305B:
Table of Contents

Advertisement

Symptom
Convection fan inoperable - oven, oven
lights, surface burner igniters operate
Oven lights inoperable - oven, surface
burner igniters operate
Oven cycle or clean light inoperable -
oven, surface burner igniters operate

Surface Burners

Quick Power Disconnect

The range has a quick power disconnect located behind
the control panel. Use this disconnect location instead
of pulling the range from the installation and unplugging
from the outlet.
1. Access control components (see Access Control
Components Assembly).
2. Disconnect Molex connector to remove power to the
range.
3. Reverse procedure for installation.
©2013 Viking Preferred Service
Possible Cause
Open convection fan motor
Open oven control board
Defective oven wiring (shorted,
open, or burned)
Open oven bulbs
Open light switch
Open door light switch
Defective oven wiring (shorted,
open, or burned)
Defective cycle or clean light
(neon)
Open oven control board
Defective oven wiring (shorted,
open, or burned)
Troubleshooting
Corrective Action
Replace convection fan motor
Replace oven control board
Repair or replace defective wiring
Replace oven bulbs
Replace light switch
Replace door light switch
Repair or replace defective wiring
Replace light
Replace oven control board
Repair or replace defective wiring
19