CAUTIONS AND WARNINGS
CHEMICAL EXPOSURE PRECAUTION
Fluence lighting systems are designed to be resilient against crop protection products Many chemicals used in the Commercial Horticultural
Industry are corrosive to electronic equipment If the luminaire is accidentally exposed to a corrosive liquid or vapor (e g VOC –Volatile Organic
Compound and H2S – Hydrogen Sulfide) the luminaire must be rinsed with clean water as soon as possible The product warranty will no longer
apply if the product is exposed or remains in the corrosive environment It is recommended the luminaires be removed and protected from the
corrosive environment during all periods of disinfection or sanitization of the facility
CALIFORNIA PROPOSITION 65 WARNING
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm For more
information: www P65Warnings ca gov
PHOTOBIOLOGICAL HAZARD SAFETY
Photobiological safety of lamps and lamp systems (IEC/EN 62471 and TR 62778) This International Standard describes the photobiological safety of
lamps and lamp systems including luminaires The rating of this product according to this standard can be found in the table below
Ordering Code
RP-x-BP6-800-STD-JVG-RST1-S
RP-x-BP6-800-150-JVG-RST1-S
RP-x-BP6-1K-STD-JVG-RST1-S
RP-x-BP6-1K-150-JVG-RST1-S
RP-x-BP9-800-STD-JVG-RST1-S
RP-x-BP9-800-150-JVG-RST1-S
RP-x-BP9-1K-STD-JVG-RST1-S
RP-x-BP9-1K-150-JVG-RST1-S
All Others
CAUTION: POSSIBLY HAZARDOUS OPTICAL RADIATION EMITTED FROM
THIS PRODUCT DO NOT STARE AT THE OPERATING LAMP MAY BE
These photobiological safety markings are based on testing of the light output characteristic of a single horticultural luminaire Increased exposure
risk to facility personnel may be present depending upon the number of horticultural luminaires and their placement and/or positioning within the
plant growth facility
It is the responsibility of the plant growth facility to address these risks at the facility level and to ensure that people entering the plant growth areas
while the lights are on are aware of these risks and that appropriate safeguards are in place
ETL Rating: RAPTR fixtures are rated suitable for wet locations A "wet location" is defined as an interior or exterior location in which water or other liquids
may drip, splash or flow on or against the electrical components of a lighting fixture RAPTR Series luminaires are certified to meet UL standards (ETL) from the
Intertek safety consulting and certification company Systems are cETL listed and are rated IP66 by IEC standard 60598-1
6
Radiation hazard -
Actinic UV 200-400 nm
Retinal Blue Light (small source) 300-700 nm
Exempt Group
(None)
Risk Group 1
(Low)
Exempt Group
(None)
Retinal Blue Light Radiation Hazard - RISK GROUP 2
HARMFUL TO THE EYE
Radiation hazard -
Minimum viewing distance
Risk Group 2
(Moderate)
Risk Group 2
(Moderate)
Risk Group 1
(Low)
Actinic UV Radiation Hazard - RISK GROUP 2
CAUTION: UV EMITTED FROM THIS PRODUCT EYE OR SKIN IRRITATION
MAY RESULT FROM EXPOSUREMINIMIZE EXPOSURE TO EYES OR SKIN USE
All Other Radiation Hazards
(meter/inch)
Exempt Group
2 162 / 85 118
(None)
Exempt Group
1 557 / 61 299
(None)
Exempt Group
N/A
(None)
APPROPRIATE SHIELDING
Need help?
Do you have a question about the RAPTR and is the answer not in the manual?
Questions and answers