SPECIFICATIONS
2 in 1 design with bottle filler and bubbler.
Drinking taps are designed to operate at full mains pressure.
The rubber mouthguard is resistant to fungal and bacterial attack and has a high resistance to sunlight.
Vandal resistant push buttons.
Adjustable built-in flow restrictor.
IMPORTANT: All Ezy-Drink
in good working order.
*As 'lead free' is not currently defined by law in Australia and New Zealand, we have based our definition of Lead Safe™ on the requirements of s1417 of the USA's Safe Drinking
Water Act (SDWA) and the relevant US standards NSF61 / NSF372. The SDWA defines 'lead free' as "not more than a weighted average of 0.25% lead when used with respect
to the wetted surface of pipes, pipe fittings, plumbing fittings and fixtures".
WARNINGS: Special attention to be paid on notes, photos, images, or drawings of assembly steps marked
with the warning symbol.
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Working Temperature Range (°C)
Nominal Flow Rate (LPM)
Construction
Finish
NOTE: Galvin Engineering continually strive to improve their products. Specifications may change without
notice.
TOOLS REQUIRED
Power drill
Wrench
Screwdriver
© Galvin Engineering Pty Ltd
2 in 1 Bottle Filler & Bubbler
®
2 in 1 taps are tested in accordance with AS/NZS 3718 and leave our premises
Version 1, 13
½" BSP Female
Rubber Mouthguard/Bottle Filler
Push Button
Min
50
Max
500
Min
5
Max
60
2.98
Brass
Chrome
th
June 2023, Page 1 of 4

Advertisement

loading

Summary of Contents for Galvin Engineering Ezy-Drink CP Lead Safe 2 in 1 Bottle Filler & Bubbler Hob Mount

  • Page 1 Working Pressure Range (kPa) Working Temperature Range (°C) Nominal Flow Rate (LPM) 2.98 Construction Brass Finish Chrome NOTE: Galvin Engineering continually strive to improve their products. Specifications may change without notice. TOOLS REQUIRED  Power drill  Wrench  Screwdriver...
  • Page 2 Anti-rotation can be achieved (if required) by using the M4 holes in the flange.  Note: Before installation, all lines must be flushed. We recommend that a line strainer be installed prior to drinking taps to eliminate any foreign material. © Galvin Engineering Pty Ltd...
  • Page 3 June 2023, Page 3 of 4 INSTALLATION INSTALLATION COMPLIANCE: Galvin Engineering products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.
  • Page 4 WARRANTY The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose.

This manual is also suitable for:

170.00.13.00